Programming The Receiver Operating Frequency & High Speed Conditioning Of Fan Control; Important - Luminance Brands rathy ireland HOME MIDWAY ECO LED CF955LBS00 Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7.8: Storage Bracket Installation
A Storage Bracket is provided for holding your Remote
Control when not in use. If you desire to use the
Bracket, install it on a wall that is away from excess
heat or humidity.
Slide the Wall Bracket Cover up to expose the Screw
Holes for installation (Figure 33).
Position the Bracket on the wall in desired location.
Install the Two Screws (supplied) into the Wall Bracket
and tighten to secure to Wall.
Slide the Wall Bracket Cover back down over the
Screws.
8. Programming the Receiver Operating Frequency
& High Speed Conditioning of Fan Control
8.1
IMPORTANT: Ceiling fan blades MUST be installed
before high speed conditioning can begin.
Within 1 minute of restoring electricity to the Ceiling
Fan, push and hold the FAN POWER OFF Button (
for 3 to 5 seconds to set the code in the receiver.
The Ceiling Fan lights (if installed) will blink to indicate
the transmitted has been paired with the receiver.
IMPORTANT: Immediately after successful pairing,
the ceiling fan will automatically begin high speed
conditioning of the motor. During conditioning, the
electronic motor control software is calculating
speeds for the 2nd through 5th speed settings
based on the blades that were installed on the fan.
The Fan will run for approximately 2 minutes in the
upward direction then reverse direction to down flow
and run an additional 2 minutes. When conditioning is
complete, the Fan will come to complete stop.
COVER
STORAGE
BRACKET
HOLES (2)
SCREWS (2)
Figure 33
IMPORTANT: Do not interrupt the conditioning until
the fan comes to a complete stop in approximately
5 minutes. All functions of the control will be
rejected during conditioning.
High speed conditioning is now complete.
)
8.2
If programming is unsuccessful, retry the previous
instructions after cycling the Wall Switch to restart the
1 minute programming time period.
If still unsuccessful, shut off the electricity at the fuse
box or breaker panel and change the Remote Control
Frequency (page 16). After changing the frequency
settings, repeat instruction 8.1 of this section within one
minute of restoring the electricity.
19
luminancebrands.com
Please contact 1-800-777-4440 for further assistance
ETL Model No.: CF955L

Publicité

Table des Matières
loading

Table des Matières