Programming The Receiver Operating Frequency - Luminance Brands Kathy Ireland Home LINDBERGH ECO Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9. Programming the Receiver Operating Frequency

& High Speed Conditioning of Fan Control
-- Important - Read This Section Carefully and Follow
the High Speed Conditioning Instructions Closely --
PROGRAMMING THE RECEIVER
OPERATING FREQUENCY & HIGH SPEED
CONDITIONING OF FAN CONTROL
IMPORTANT: Ceiling Fan Blades MUST be installed
before High Speed Conditioning can begin.
NOTE: If using a 3-way Switch Installation, ensure
that both Wall Controls are using the same Switch
Code.
9.1
Flip the Wall Control ON/OFF Switch (
"OFF" ( O ) position .
Restore Electricity to the Ceiling Fan Branch Circuit at
the Circuit Breaker or Fuse Box .
Flip the Wall Control ON/OFF Switch to "ON" (
position .
Within one minute of flipping the Switch to "ON", push
and hold the FAN POWER OFF Button (
seconds to set the Code in the Receiver . The Ceiling
Fan Lights (if installed) will blink to indicate the Wall
Control Code has been paired with the Receiver .
IMPORTANT: Immediately after successful pairing,
the Ceiling Fan will automatically begin High Speed
Conditioning of the Motor. During conditioning, the
Electronic Motor Control Software is calculating
Speeds for the 2nd through 5th Speed settings
based on the Blades that were installed on the Fan.
9.2
The Fan will run for approximately 2 minutes in the
Upward Direction then Reverse Direction to down flow
and run an additional 2 minutes . When Conditioning is
complete, the Fan will come to complete stop .
IMPORTANT: Do not interrupt the Conditioning until
the Fan comes to a complete stop in approximately
5 minutes. All functions of the Control will be
rejected during Conditioning.
9.3
) to the
High Speed Conditioning is now complete .
9.4
If programming is unsuccessful, retry the above
)
instructions after cycling the Wall Control ON/OFF
Switch to restart the 1 minute programming time period .
9.5
) for 3 to 5
If still unsuccessful, shut off the Electricity at the Fuse
Box or Breaker Panel and change the Wall Control
Frequency (Section 7 .2, Page 19) . After changing the
Frequency Settings, repeat instructions 9 .1 - 9 .5 of this
section within one minute of restoring the Electricity .