9. Programming the Receiver Operating Frequency
& High Speed Conditioning of Fan Control
-- Important - Read This Section Carefully and Follow
the High Speed Conditioning Instructions Closely --
PROGRAMMING THE RECEIVER
OPERATING FREQUENCY & HIGH SPEED
CONDITIONING OF FAN CONTROL
IMPORTANT: Ceiling Fan Blades MUST be installed
before High Speed Conditioning can begin.
NOTE: If using a 3-way Switch Installation, ensure
that both Wall Controls are using the same Switch
Code.
9.1
Flip the Wall Control ON/OFF Switch (
"OFF" ( O ) position .
Restore Electricity to the Ceiling Fan Branch Circuit at
the Circuit Breaker or Fuse Box .
Flip the Wall Control ON/OFF Switch to "ON" (
position .
Within one minute of flipping the Switch to "ON", push
and hold the FAN POWER OFF Button (
seconds to set the Code in the Receiver . The Ceiling
Fan Lights (if installed) will blink to indicate the Wall
Control Code has been paired with the Receiver .
IMPORTANT: Immediately after successful pairing,
the Ceiling Fan will automatically begin High Speed
Conditioning of the Motor. During conditioning, the
Electronic Motor Control Software is calculating
Speeds for the 2nd through 5th Speed settings
based on the Blades that were installed on the Fan.
10. Energy Efficient Use of Ceiling Fans
Ceiling fan performance and energy savings rely
heavily on the proper installation and use of the
Ceiling Fan . Here are a few tips to ensure quality and
product performance .
C h o o s i n g
t h e
A p p r o p r i a t e
Location.
Ceiling Fans should be installed,
or mounted, in the middle of the room and at least
7-feet above the floor and 18-inches from the
walls . If ceiling height allows, install the Fan
8 - 9 feet above the floor for optimal airflow .
Consult your Luminance Brands Retailer for optional
mounting accessories .
Using the Ceiling Fan Year Round. In the summer,
use the Ceiling Fan in the counter-clockwise direction .
9.2
The Fan will run for approximately 2 minutes in the
Upward Direction then Reverse Direction to down flow
and run an additional 2 minutes . When Conditioning is
complete, the Fan will come to complete stop .
IMPORTANT: Do not interrupt the Conditioning until
the Fan comes to a complete stop in approximately
5 minutes. All functions of the Control will be
rejected during Conditioning.
9.3
) to the
High Speed Conditioning is now complete .
9.4
If programming is unsuccessful, retry the above
)
instructions after cycling the Wall Control ON/OFF
Switch to restart the 1 minute programming time period .
9.5
) for 3 to 5
If still unsuccessful, shut off the Electricity at the Fuse
Box or Breaker Panel and change the Wall Control
Frequency (Section 7 .2, Page 16) . After changing the
Frequency Settings, repeat instructions 9 .1 - 9 .5 of this
section within one minute of restoring the Electricity .
The airflow produced by the Ceiling Fan creates
a wind-chill effect, making you "feel" cooler .
Select a Fan speed that provides a comfortable
breeze, lower speeds consume less energy .
In the winter, reverse the motor and operate the
M o u n t i n g
Ceiling Fan at low speed in the clockwise direction .
This produces a gentle updraft, which forces warm
air near the ceiling down into the occupied space .
Remember to adjust your thermostat when using your
Ceiling Fan - additional energy and dollar savings could
be realized with this simple step!
Turn Off When Not in the Room. Ceiling Fans cool
people, not rooms . If the room is unoccupied, turn OFF
the Ceiling Fan to save energy .
21
luminancebrands.com
Please contact 1-800-777-4440 for further assistance
ETL Model No.: CF788