Maxitrol Regulator Conversion; Setting Manual Valve Screws For Cooktop / Rangetop; Screw Driver For Valve Screw Setting - Thermador Professional PLPKIT Instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Maxitrol regulator conversion

Remove conversion cap with a 7/8" socket or wrench.
Snap-out stem from bottom of the cap, flip stem over to
show "LP" end, and snap stem back into the cap, as
shown.
Flip Stem

Setting Manual Valve Screws for Cooktop / Rangetop

Screw driver for valve screw setting

A precision screwdriver with high-strength blade, similar to
the *Wiha no. 26033, with 1/8" [3.0mm] wide, .020"
[0.50mm] thickness tip, shown below, should be used to re-
position the bypass screws for minimum flow settings on
manual valves.
Re-install conversion cap -configured for LP gas- back
into top of the Maxitrol regulator.
*Used by permission from Wiha Quality Tools division of Willi
Hahn Corporation USA.