Lp Regulator Conversion - Thermador PROFESSIONAL Pro Grand PRD364JDGC Instructions

Masquer les pouces Voir aussi pour PROFESSIONAL Pro Grand PRD364JDGC:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5. Disconnect the igniter.
A.) Disconnecting a Two Piece Igniter
1) Carefully pull up on the burner base.
Electrode
Ignitor Housing
Ignitor Wire
B.) Disconnecting a Single Piece Igniter
1) Carefully pull up on the burner base.
2) Disconnect the female terminal on the spark wire
from the male terminal on the electrode for each
burner.
IMPORTANT: The locking tab on the female
connector must be depressed to release from the
terminal on the electrode.
Electrode
6. From each burner pedestal, remove the burner
pedestal screws with a T-30 Torx screwdriver.
Burner Pedestal
Burner Pedestal
Burner Pedestal
Installation Instructions
Burner Base
Burner Base
Ignitor Wire
Venturi
7. Carefully remove the burner pedestal and the venturi.
8. Remove the spill trays by rotating the trays up and out
the back.
9. Remove the heat shield, on some models. Some
models have a double-width shield that extends under
adjacent spill tray.

LP Regulator Conversion

The gas regulator is located in the cooktop, left side of
appliance. Exact location will vary per model.
2. Read the letters on the stem. You will see "NAT" at
the bottom of the stem. Snap-out the plunger from
bottom of the conversion cap. Flip the stem over to
the "LP" end, and snap the plunger back into the
cap, as shown.
1. Remove
conversion cap
with a 7/8" socket
or wrench.
English | 4 |