Replace the Wok Orifice in Pro Cooktop—
if so equipped
•
Remove the two screws that attach the pilot burner to
the bracket on the Wok Top Support Assembly.
•
Lift the Top Assembly straight up, away from the Wok
Chassis a few inches, and then remove the Wok
Burner.
•
Lift out the Wok Top Support Assembly. This will
expose the Safety Valve.
•
Use a 1/2" deep-well socket to remove the hood orifice
from the safety valve.
English 10
Wok Safety Valve with Hood Orifice
•
The LP orifice for the Wok is a #54 drill (stamped "54"),
which is sized to produce 24,500 BTU/hr. [7.17 kW],
when using Propane (LP) Gas. The orifice diameter
could also be 1.40mm; in which case, the hood orifice
could have a "140" or "1.40MM" stamp.
NOTE:
The pilot burner does not require orifice conversion for
operation on Propane Gas.
•
Pre-adjust the air shutter on the Wok Burner to fully
open position.
•
Replace the Wok Top Assembly.
•
Re-install the wok burner. Make sure that the burner's
venturi is properly positioned on the hood orifice, and
that the bottom of the burner head is positioned
between the pins on the cross member at the base of
the top support.
•
Re-attach the pilot burner to the bracket on the Wok
Top Support.