4. Use an extra large, slotted screwdriver, with .60" X
.060" blade, to re-install LP cap.
5. Re-insert cap in top of the regulator with recess up,
"LP" visible. Press down and rotate clockwise to lock
cap position.
English 6

Maxitrol regulator conversion:

1. Remove conversion cap with a 7/8" socket or wrench.
2. Snap-out stem from bottom of the cap, flip stem over to
show "LP" end, and snap stem back into the cap, as
shown.
Flip Stem
3. Re-install conversion cap —configured for LP gas—
back into top of the Maxitrol regulator.