Napoleon Riverside Série Manuel D'installation Et D'opération page 37

Masquer les pouces Voir aussi pour Riverside Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

symptom
F lam es are very
Door is ajar.
ag g ressive.
Venting action is too great.
Appliance won't
No power to the system.
perform any
functions
Receiver switch in wrong
position (if equipped).
On/off switch in wrong posi-
tion.
Transmitter isn't operational
(if required).
Light won't function
Light bulb burnt out.
(if applicable).
Light harness damaged.
Switch in wrong position.
No power to lights.
Blower won't
Blower kit not wired correctly.
function (if appli-
cable).
V a ria b le sp eed sw itch in w ro n g
p o sition .
Thermal disc not hot enough
to operate blower.
problem
-
E nsure d o o r is secu red p ro p erly .
-
Check to ensure venting is properly sealed or restrict vent exit with
restrictor plate (not available in all appliances).
-
Check breaker to verify it is in the "on" position.
-
Ensure module is wired to power correctly.
-
Verify that the 3-position switch on the receiver is in the
remote position (middle).
-
Verify that the switch is in the "on" position.
-
Check battery power and battery orientation.
-
Change the bulb.
-
Replace the harness.
-
Ensure switch is in "on" position.
-
Ensure power transformer is plugged into junction box and
lights are wired correctly.
-
Ensure blower is wired correctly (see "optional blower
installation" section).
-
Turn switch away from "off" position.
-
Thermal disk must reach 32°C (90°F) before blower will
operate. Ensure swithc surface is tight to hot metal surface.
troubleshooting
test solution
W415-2978 / A / 10.07.21
EN
37

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Riverside gss36cfneRiverside gss36cfpe

Table des Matières