VENTURI ADJUSTMENT

This appliance has an air shutter that has been factory set open according
to the chart below:
Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carboning. Opening the air shutter will cause a
more blue flame, but can cause flame lifting from the burner ports. The
flame may not appear yellow immediately; allow 15 to 30 minutes for the
final flame color to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER!
VENTURI ADJUSTMENT CHART
FUEL
NG
LP

RESTRICTOR PLATE INSTALLATION

Vertical terminations may display a very active flame. If
this appearance is not desirable, the vent exit must be
restricted using restrictor plate, W500-0205 (supplied with
unit). This reduces the velocity of the exhaust gases,
slowing down the flame pattern and creating a more
traditional appearance.
Install the plate over the exhaust outlet.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax (705)722-6031 •
(C)HDX40
3/16"
7/16"
VENTURI
BURNER
AIR
SHUTTER
OPENING
ORIFICE
49.1
W415-0902 / 03.24.10
www.napoleonfireplaces.com