2
FIRESTOP VENTING INSTALLATION
The firestop assembly must be installed with the vent shield to the top.
Do not fill the cavity between the pipe and the framing with any type of material.
Terminals must not be recessed into a wall or siding more than the depth of the return flange of the
This application occurs when venting through an exterior wall.
Having determined the correct height for the air terminal
location, cut and frame a hole in the exterior wall as
illustrated to accommodate the fi restop assembly. Dry
fi t the fi restop assembly before proceeding to ensure
the brackets on the rear surface fi t to the inside surface
of the horizontal framing.
The length of the vent shield may be cut shorter for
combustible walls that are less than 8 1/2" thick but
the vent shield must extend the full depth of the combustible
wall.
A. Apply a bead of caulking (not supplied) around the corner edge of
the inside surface of the fi restop assembly, fi t the fi restop assembly to the
hole and secure using the 4 screws W570-0026 (supplied in your manual
baggie).
B. Once the vent pipe is installed in its fi nal position, apply high temperature sealant W573-0007 (not supplied)
between the pipe and the fi restop.
USING FLEXIBLE VENT COMPONENTS
REFER TO THE APPLIANCE INSTALLATION INSTRUCTIONS
ADDING VENT LENGTH
If more vent pipe needs to be used to reach the
fi replace, couple them together as illustrated. The
vent system must be supported approximately every
3 feet for both vertical and horizontal runs. Use
noncombustible strapping to maintain the minimum
clearance to combustibles.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax (705)722-6031 •
WARNING
!
mounting plate.
VENT
SHIELD
CAULKING
FIRESTOP
SPACER
HI-TEMP
SEALANT
OUTER
FLEX PIPE
3
11
/
"
8
7
9
/
"
8
DETERMINE
THE
CORRECT
HEIGHT
FINISHING
MATERIAL
#8 X 1/2" SELF DRILLING
SCREWS & WASHERS
INNER COUPLER
OUTER COUPLER
OUTER
FLEX PIPE
INNER
FLEX PIPE
www.napoleonfireplaces.com