THESE INSTRUCTIONS ARE TO BE USED IN CONJUNCTION WITH THOSE FOR THE GPV AND THE APPLIANCE.
THIS INFORMATION SUPERSEDES THAT IN THE APPLIANCE INSTALLATION INSTRUCTIONS.
CONSUMER: RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Included in this kit:
W500-0431
Plate, restrictor
W750-0127
Wire, 14" (355.6mm) jumper
W750-0285
Wire harness, unit (Electrical Box)
W750-0291
Wire, Switch
TERMINAL INSTALLATION
REFER TO GPV INSTALLATION INSTRUCTIONS
WIRING DIAGRAM AND INSTALLATION
REFER TO GPV INSTALLATION INSTRUCTIONS SECTIONS "SIT 820 NOVA MILLIVOLT FOR USE WITH SINGLE
POLE SWITCH, COMPLETE WITH GPV POWER VENT TERMINAL" OR "DEXEN 6003-3V FOR USE WITH A SINGLE
POLE SWITCH, COMPLETE WITH GPV POWER VENT TERMINAL"
VENTING INSTALLATION
USE ONLY WOLF STEEL APPROVED FLEXIBLE VENTING COMPONENTS.
REFER TO THE APPLIANCE INSTALLATION INSTRUCTIONS FOR ASSEMBLY AND CLEARANCE REQUIREMENTS.
VENT LENGTHS
It is recommended that the gas power vent be used with a gas appliance that is equipped with Electronic Ignition. When
installing the venting, these parameters supersede the Vent Installation Section in the appliance's Installation and
Operating Instructions, as well as the following guidelines:
All venting confi gurations apply to both top and rear vented units.
Maximum vent run is 50 feet (15.2m) total.
PVA36-1 POWER VENT ADAPTOR KIT
INSTALLATION INSTRUCTIONS
INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE.
B G
D I
L L U
S T
R A
T E
D
W415-1162 / 03.20.13

Publicité

Table des Matières
loading

Sommaire des Matières pour Napoleon PVA36-1

  • Page 1 PVA36-1 POWER VENT ADAPTOR KIT INSTALLATION INSTRUCTIONS INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE. THESE INSTRUCTIONS ARE TO BE USED IN CONJUNCTION WITH THOSE FOR THE GPV AND THE APPLIANCE. THIS INFORMATION SUPERSEDES THAT IN THE APPLIANCE INSTALLATION INSTRUCTIONS. CONSUMER: RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2 SIMPLE REAR VENT MAX H MIN H 50 FEET (15.2M) 10 FEET (3.1M) SIMPLE TOP VENT MAX H+V MIN H+V MAX ELBOWS 50 FEET (15.2M) 10 FEET (3.1M) SIX 90° MULTI ELBOW Multi-elbow installations are possible up to a maximum of six 90°. ELBOWS V1+V2+V3+ V1+V2+V3+...
  • Page 3: Restrictor Plate Installation

    RESTRICTOR PLATE INSTALLATION To ensure proper appliance operation, a restrictor plate (supplied) is required for either top or rear exit venting. IMPORTANT! The restrictor plate (supplied) has a knockout which must remain when used with the BGD/BCDV36. This knockout must be KNOCKOUT removed when installed in the GD/CDV36.
  • Page 4: Installation De La Terminaison

    INSTRUCTIONS D’INSTALLATION DE LA TERMINAISON MÉCANIQUE PVA36-1 INSTALLATEUR : LAISSEZ CE MANUEL AVEC L’APPAREIL. CES INSTRUCTIONS DOIVENT ÊTRE UTILISÉES CONJOINTEMENT AVEC CELLES DU GPV ET DE L’APPAREIL. CES INFORMATIONS REMPLACENT LES INSTRUCTIONS D’INSTALLATION DE L’APPAREIL. PROPRIÉTAIRE : CONSERVEZ CE MANUEL POUR CONSULTATION ULTÉRIEURE.
  • Page 5: Évacuation Arrière, Configuration Simple

    ÉVACUATION ARRIÈRE, CONFIGURATION SIMPLE H MAXIMUM H MINIMUM 50 FEET (15.2M) 10 FEET (3.1M) ÉVACUATION SUR LE DESSUS, CONFIGURATION SIMPLE H+V MAXIMUM H+V MINIMUM COUDES MAXIMUM 50 FEET (15.2M) 10 FEET (3.1M) SIX 90° COUDES MULTIPLES Les installations à coudes multiples sont possibles jusqu’à un maximum de six coudes de 90°.
  • Page 6: Installation De La Plaque De Restriction

    INSTALLATION DE LA PLAQUE DE RESTRICTION Une plaque de restriction (fournie) est nécessaire pour les appareils ventilés par le dessus ou par l’arrière, afin d’assurer un fonctionnement adéquat. IMPORTANT! La plaque poinçonnée de la plaque de restriction (fournie) doit demeurer en place lorsque les modèles BGD/BCDV36 sont installés.