7.3.6

CLEAR GROUP PARAMETERS

The CLEAR GROUP PARAMETER function is for resetting to their nominal values all group parameters (see the ''LA
NETWORK MANAGER'' user manual) such as Name, Gain, Delay, and Contour EQ defined in the LA NETWORK
MANAGER software.
To reset the group parameters, select the CLEAR GROUP PARAMETERS function and follow this procedure (see also
Figure 20):
1. Press the OK key or the encoder wheel, the LCD will display "ARE YOU SURE ?" (or press the ESC key to
cancel and return to the last menu). The "OUTPUT MUTED" message indicates that all outputs will be muted
in the process.
2. Press the OK key or the encoder wheel once again to reset all group parameters (or press the ESC key to
cancel and return to the last menu). All outputs will be muted and the LCD will return to the main screen.
CLEAR GRP PARAM
Notes: If the controller is not assigned to a group the message ''NO GROUP DEFINED'' appears and the CLEAR
GROUP PARAMETER function is not accessible.
It is possible to check if a controller is part of a group and to identify its name by pressing and holding either the IN A or
IN B key. The name of the group will appear at the bottom right of the LCD (Figure 21 shows that the controller
belongs to a group named SUBLEFT).
The group parameters remain active even if the controller is disconnected from the PC remote running LA NETWORK
MANAGER (controller in the standalone mode), and they are not preset dependent (they will remain the same even if a
new preset is loaded).
Therefore, when getting a unit for a standalone application that has been previously used within a network,
L-ACOUSTICS
®
recommends using the CLEAR GROUP PARAMETERS function in order to clear all group parameters
as they cannot be seen and accessed via the front panel user interface.
LA8_UM_ML_1.2
ARE YOU SURE ?
OK
OUTPUT MUTED
ESC
Figure 20: Resetting group parameters
Figure 21: Controller's group indication
w w w . l - a c o u s t i c s . c o m
40:SB28_60