6.2

Cooling

The amplified controller uses a forced air cooling system to maintain a low and even operating temperature. All fan
cooled L-ACOUSTICS
®
amplified controllers have front to rear airflow. Therefore when stacking more than one unit in
a rack, mount units directly on top of each other or close any open space in the rack with blank panels.
!
If the controller is rack-mounted do not block front or rear air vents with front or back panels or
doors. If this cannot be achieved a forced ventilation system has to be used.
If the controller is installed in an enclosed rack the open area at the back of the controller must be
at least 140 cm
Ensure that the front filter system is clean and dust free (see section 8.2).
CAUTION
6.3

Operating voltage

Operating voltage range and frequency are indicated on the controller back panel.
Only connect the controller to an appropriate AC circuit and outlet.
If you are unsure of the output voltage of your AC mains please consult your local electrician.
VOLTAGE
The following table gives the LA8 Power Supply Data in nominal use (4 Ω, 1/8 of maximum output power [see section 6.7]):
Voltage (V)
100
120 / 230
6.4

Connecting to AC mains

The amplified controller is supplied either with a European, US, or Japanese AC power plug depending on the country of
use. If the power plug is not appropriate it can be cut off and wired to a suitable plug in the following manner:
Country
Europe
USA
Japan
Changing the plug must be done by qualified personnel only.
The specific safety regulations of the country of use must be strictly applied.
The plug must be approved for the specific voltage and current rating given in Table 1.
The ground connection of the supplied AC power cord is a safety feature. Do not attempt to disable
it by using an adaptor or by other methods.
VOLTAGE
Note: Warranty will not cover damages caused by a wiring error.
LA8_UM_EN_1.2
3
per controller.
Table 1: LA8 Power supply data in nominal use
Mains Frequency (Hz)
50 - 60
50 - 60
Table 2: Power cord wiring color code
Live
Brown
Black
Black
w w w . l - a c o u s t i c s . c o m
Current (A)
Power Consumption (W)
25
21 / 11
Neutral
Blue
White
White
1500
1500
Earth
Green / Yellow
Green
Green
16 en