BE24
7 - PROTECTION FUSES
Position
Value
F1
10A
F2
3,15A
F3
8A
2A
F4
8 - WARNING LEDs
Position
Colour
L1
GREEN
L2
GREEN
L3
RED
L4
RED
L5
RED
L6
RED
L7
BLUE
Type
Protects battery power circuit.
F
Protects external accessories, electric lock and flashing light.
F
Protects the circuit board.
F
Protects the transformer.
F
Signal
Comes on when the START control is activated from the terminal board or the receiver.
START
Comes on when the PED control is activated from the terminal board or the receiver.
PED
PHOTO1 Always on. Comes off when the contact of terminal PHOTO 1 is opened.
PHOTO2 Always on. Comes off when the contact of terminal PHOTO 2 is opened.
Always on. Comes off when the resistance value of terminal SAFETY is wrong.
SAFETY
Always off, comes on when LEARN button is pressed.
RX
0,2s ON 0,2 OFF
30s ON
0,2s ON-4s OFF
INFO
0,2s ON - 0,2s OFF
0,2s ON - 4s OFF
1s OFF - 0,6s ON - 1s OFF
X2
1s OFF - 0,6s ON - 0,6s OFF
0,6s ON - 1s OFF
X2
Description
Description
The control board is locked, it's necessary to execute a new travel
learning procedure.
The control board is in pre-learning phase, aftre pressing MEMO
button.
During sleep time, the control board is set to work with KUDA -
AGO424E - AGO624E. operator.
During sleep time, the control board is set to work with SERRA320 -
SNAPPER - AGO424E/S - AGO624E/S..
Motor 1 encoder error, travel learning procedure failed.
Motor 2 encoder error, travel learning procedure failed.
17
UK