GiBiDi BE24 115V Instructions Pour L'installation page 19

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

BE24
9 - DIP SWITCH DIP1
The settings are stored during the rest phase (gate closed).
The default settings are highlighted in the boxes with grey background.
DIP
Function
1_7
PRE-FLASHING
1_8
GATE PHASE
1_9
SHIFT TIME
1_10
WATER HAMMER
10 - DIP SWITCH DIP2
The settings are stored during the rest phase (gate closed).
The default settings are highlighted in the boxes with grey background.
DIP
Function
DECELERATION
2_1
SPEED
MOVEMENT SPEED
changing this setting will
2_2
reset the control board and
a new learning cycle will be
required.
FAST CLOSING
2_3
Status
Enables pre-flashing of 3 seconds before motor activation during opening and closing.
ON
OFF
Disables pre-flashing.
OFF
Disables gate phase shift time.
OFF
OFF
Motor 2 delay during opening: 3 seconds.
Motor 1 delay during closing: 3 seconds.
ON
ON
Motor 2 delay during opening: 3 seconds.
Motor 1 delay during closing: 6 seconds.
OFF
ON
Motor 2 delay during opening: 3 seconds.
Motor 1 delay during closing: 9 seconds.
ON
Enables the water hammer function during opening to help electric lock release.
Operation: at the START command, the following will occur in sequence:
- electric lock activation;
ON
- closing pulse of 1 sec;
- opening;
- electric lock release after 2 sec.
OFF
Disables the water hammer function.
Status
ON
Deceleration speed equal to 50% of the maximum speed.
Deceleration speed equal to 30% of the maximum speed.
OFF
ON
Speed during normal movement equal to 100% of the maximum speed.
Speed during normal movement equal to 80% of the maximum speed.
OFF
Enables fast closing function.
ON
Operation: Reduces the stand-by time to 3 seconds following interception and
subsequent freeing of the photocells. Active only on photocell 1.
Fast closing disabled.
OFF
Description
Description
19
UK

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

As05870/115v

Table des Matières