Step B1: Preprogramming the Somfy io-homecontrol
This guide describes set-up using a Somfy Smoove io type io-homecontrol
Position the roller shutter at its half-way position.
1)
On the wired control point, press three times
2)
and press once on
on
forth movement of the roller shutter:
The radio is activated and the drive is in
→
programming mode.
The drive remains in programming mode for ≈ 10 min.
On the io-homecontrol
3)
Λ
V
both
and
at the same time:
The roller shutter moves back and forth:
→
the control point has been preprogrammed in
the drive.
The rotation direction of the drive self-adjusts automatically during the first few cycles.
During the first few movements, the
without the need for any settings, a er maximum 2 complete cycles, from stop to stop).
For a roller shutter less than 0.5 m² (0.6 m x 0.7 m), see chapter Questions on S&SO-RS100
io HYBRID?
a
Step B2
: Setting / resetting of end limits in manual mode with the io-homecontrol
control point
This procedure is only applicable to roller shutters without rigid links and with stops.
From 3), in set mode:
The roller shutter moves more slowly during the first few seconds of movement.
•
Position the roller shutter at its half-way position.
1)
On the io-homecontrol
2)
V
simultaneously, for ≈ 5 s, until there is back and
forth movement by the roller shutter.
The drive is in set mode.
→
The drive remains in set mode for ≈ 10 min.
Move the roller shutter to the desired upper (or lower)
3)
end limit.
my,
Press
for ≈ 2 s, until there is back and forth
4)
movement by the roller shutter.
The setting for the first end limit is confirmed.
→
Move the roller shutter to the desired lower (or upper)
5)
end limit.
my
Press
, for ≈ 2 s, until there are two back and
6)
forth movements by the roller shutter.
The setting for the second end limit is confirmed.
→
The settings for the end limits are programmed.
→
The drive enters programming mode for ≈ 2 min. if no io-homecontrol
→
programmed.
Copyright © 2014 - 2016 Somfy SAS. All rights reserved.
until there is back and
control point, briefly press
®
Λ/V
orders may be inverted (they adjust automatically
control point, press
®
local control point
®
1)
2)
3)
0.5 S
Λ
and
1)
3)
5)
EN
local control point.
®
x 3
2.5 S
®
2)
5 S
4)
2 S
6)
2 S
X 2
control point is
®
Non contractual images.
57