MACHINE MAINTENANCE
FOR SAFETY: Before servicing machine, unplug
cord from wall outlet.
1. Remove and clean the pad driver/brush after each
use.
2. Clean the machine base after each use.
3. Inspect power cord for damage after each use. If
worn or damaged, replace immediately.
4. Wipe the power cord with damp cloth and neatly
coil it around cord hook and handle after each use.
5. Periodically check that all bolts and nuts are tight.
TROUBLE SHOOTING
PROBLEM
CAUSE
Machine does not
Faulty power cord.
operate.
Tripped building circuit breaker.
Faulty machine wiring.
Faulty On/Off lever switch.
Faulty motor.
The cord connection between the handle and
base is not correctly inserted.
Machine operates
Soiled Pad.
with a wobble or jerky
Improper pad/brush for application
motion.
Pad driver/brush not installed correctly.
Pad/brush unevenly worn.
Pad not properly centered.
Tennant 2120/2140 (01- -2006)
Home
Find... Go To..
STORING MACHINE
1. Remove brush/pad driver from machine and neatly
coil cord around cord hook and handle.
2. Store machine in a dry area in the upright position.
WARNING: Do Not Use Outdoors. Do Not
Expose to Rain. Store Indoors.
RECOMMENDED STOCK ITEMS
Refer to the Parts List Section for recommended stock
items. Stock Items are clearly identified with a bullet
preceding the parts description as shown.
SOLUTION
Contact Service Center.
Reset circuit breaker in building.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Ensure correct cord connection.
Replace Pad.
Change to proper pad/brush.
Remove and reinstall pad driver/brush.
Replace pad/brush.
Remove and reinstall pad.
OPERATION