Draining Tanks; Draining Recovery Tank; Draining Solution Tank; Machine Maintenance - Tennant EX-CAN-15-HP Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATION
EN
WARNING: Do Not Pick Up Flammable
Materials Or Reactive Metals.
ATTENTION: Do not allow water or foam to enter
float shut- -off screen in recovery tank.
5. When finished cleaning, turn off switches and drain
recovery tank (See DRAINING RECOVERY
TANK).
6. After cleaning, relieve water pressure from
accessory tool before disconnecting hose.
Squeeze trigger for five seconds after turning off
the machine.

DRAINING TANKS

FOR SAFETY: Before leaving or servicing machine,
unplug cord from wall outlet.
ATTENTION: Use different buckets to fill and drain
machine to prevent solution system clogs.

DRAINING RECOVERY TANK

NOTE: When solution tank becomes empty, recovery
tank must be drained.
1. Turn switches off and unplug power cord.
2. Remove drain hose from holder, position hose over
floor drain and twist off knob to drain (Figure 8).
FIG. 8
3. Replace knob tightly before cleaning again.
4. After final draining, remove recovery tank lid and
rinse both tank and float shut-off screen thoroughly
to prevent odor buildup (Figure 11).

DRAINING SOLUTION TANK

1 . To drain remaining solution from solution tank,
disconnect solution hose and attach bleeder hose
(bleeder hose supplied with machine) (Figure 9).
8
Home
Find... Go To..
ATTENTION: Relieve water pressure from
accessory tool before disconnecting hose.
Squeeze trigger for five seconds after turning off
the main power switch.
2. Activate pump switch. Pump solution into an empty
bucket (Figure 9).
FIG. 9
3. Rinse solution tank with clean water to prevent
odor buildup. Run vacuum motor for 30 seconds to
discharge any moisture. Store extractor with covers
off to promote air circulation.

MACHINE MAINTENANCE

To keep machine in good working condition, simply
follow machines daily, weekly and monthly
maintenance procedures.
FOR SAFETY: When servicing machine, unplug
cord from wall outlet.
For ease of servicing, machine tank is hinged to pivot
away from chassis to allow access to inner components.
Make sure tanks are empty before opening. To open
extractor for servicing, follow these steps:
a. Unplug extractor.
b. Unlatch front two latches.
c. Lift tank upward, away from chassis (Figure 10).
FIG. 10
EX- -CAN- -15- -HP / EX- -CAN- -57- -HP (04- -10)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ex-can-57-hp900762890075019007503

Table des Matières