SECTION 3
ELECTRIC SHOCK CAN KILL! Precau-
tionary measures should be taken
to provide maximum protection
against electric shock. Be sure that
all power is off by opening the line
(wall) disconnect switch by unplug-
ging the power cord to the unit or
use proper lock out safety proce-
dures when making connections
inside of the power source.
2. 50 Hz Models - As shipped from the factory, the ESP-150 is configured for
the highest connectable voltage. If using other input voltages, the links on the
terminal board (TB) inside the unit must be repositioned for the appropriate
input voltage. See Figures 5a & 5b for input voltage configurations. To gain
access to the terminal board, open the access panel on the left side.
Fig. 5a
Input Terminal Board
380/415 Vac Models
380-400 Vac Configuration
Fig. 5b
Input Terminal Board
380/415 Vac Models
415 Vac Configuration
(Factory Supplied)