Climadiff CLIMA5K1 Notice D'utilisation page 43

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.
LED display
Shows the set temperature while on cool, heat or auto mode. While on DRY and FAN
modes, it shows the room temperature. Shows Error codes:
E0-EEPROM error.
E1-Room temperature sensor error.
E2-Evaporator temperature sensor error.
E3-Condenser temperature sensor error (on some models).
E4-Display panel communication error.
EC-Refrigerant leakage detection
malfunction(on some models).
Shows protection code:
P1-Bottom tray is full--Connect the drain hose and drain the collected water away.
If protection repeats, call for service.
NOTE: When one of the above malfunctions occurs, turn off the unit, and check for any
obstructions. Restart the unit, if the malfunction is still present, turn off the unit and
unplug the power cord. Contact the manufacturer or its service agents or a similar
qualified person for service.
Operation Method
Cooling mode
When the A/C enters cooling mode automatically or cooling mode is selected after power
ON, the cooling indicator lamp lights up.
Press Up/Down key to adjust setting temperature (17℃~30℃).
Press FAN SPEED on the remote controller to choose High/Low speed.
Fan mode
When pressing mode key or choosing Fan mode by pressing the remote controller, the wind
indicator lamp lights up.
Press FAN SPEED on the remote controller to choose High/Low speed.
Temperature can't be set.
Do not put the duct to window
Dehumidifying mode
When pressing mode key or choosing dehumidifying mode by pressing the remote
controller, the indicator lamp lights up.
After choosing this mode, operation state is determined by environmental temperature:
when environmental temperature is higher than 17℃, the operation state is the same as that
43