maintenance
EN
6.8

blower service or replacement

WARNING
!
Moving parts may cause injury. Do not operate unit with cover removed.
Risk of electric shock. Disconnect power before servicing appliance.
Turn off all electrical power to the appliance.
A.
Remove the blower from the appliance, if applicable (see "blower installation" section).
B.
Remove the 2 screws securing the cover to the blower housing (Fig. 6-5). Set the cover and screws
C.
aside.
Remove the 4 screws securing the retainer to the blower housing (Fig. 6-6). Slide blowers (attached
D.
to retainer) out of the housing deflectors and lift them up. Set screws and blowers (attached to retainer)
aside.
Cover
If dust and debris have accumulated, vacuum the
E.
blowers and blower housing prior to re-installation.
If blower replacement or service is required, remove the
F.
8 screws securing the blowers to the retainer (Fig. 6-7).
Reverse these steps to reinstall the blower.
G.
THERMODISC
FAN-SPEED CONTROL
Wiring Diagram
28
W415-2838 / A / 08.20.20
Appliance hidden
for clarity.
Fig. 6-5
POWER
CORD
G
POWER
FAN
FAN
CORD
Fig. 6-7