5.3

air control

WARNING
!
This wood appliance has a manufacturer-set minimum low burn rate that must not be altered. It is against
federal regulations in the United States to alter the setting or otherwise operate this wood appliance in a
manner inconsistent with operating instructions in this manual.
Draft is the force which moves
air from the firebox up through
the chimney. The amount of
draft in your chimney depends
on the length and diameter of
chimney, local geography, nearby
obstructions and other factors
including the amount of heat
generated by the fire which can
be measured by an appliance
thermometer.
Before adjusting the air control,
install the knob (supplied) by
screwing it onto the end of the air
control rod (Fig. 5-1).
Pushing the air control
all the way in reduces the
temperature. The draft can be
adjusted from low to high by
moving the handle in and out (Fig.
5-1).
Inadequate draft may cause back-puffing into the room through the appliance and chimney connector points
and may cause plugging of the chimney. Too much draft may cause an excessive temperature in the appliance,
glowing red appliance parts or chimney connectors or an uncontrollable burn which can lead to a chimney fire or
permanent damage to the appliance.
Do not operate your appliance for longer than 30 minutes with the draft control on "HIGH" (fully open).
5.4
fire extinguishers / smoke & carbon monoxide detectors
note:
Always check your smoke and CO detectors are working properly.
All homes with a solid fuel burning appliance should have at least one fi re extinguisher in a central location,
known to all, at least one smoke detector and carbon monoxide (CO) detector in the room containing the
appliance. If the smoke detector sounds an alarm, correct the cause but do not deactive or relocate the smoke
detector. If the carbon monoxide detector sounds an alarm, immediately vent the area, evacuate and call your
local fi re department.