Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

S4 BRICK AND BAFFLE INSTALLATION INSTRUCTIONS
OPERATION OF THE APPLIANCE WITHOUT THE BAFFLES CAN RESULT IN EXCESSIVE TEMPERATURES
THAT COULD DAMAGE THE APPLIANCE, CHIMNEY AND THE SURROUNDING ENCLOSURE.
With appliance and chimney installation completed, move the bricks into place for your appliance as illustrated.
A.
Install the bottom bricks, working from the back of the appliance forward.
B.
Before installing the back bricks, loosen the screw holding the brick retainer and ensure that it has been moved forward. Install
the six bricks along the back wall by pivoting the bricks up under the brick retainer. Re-tighten the screw.
C.
Install the fi rst two rows of side bricks as shown in the illustration below.
D.
Pivot the fi bre baffl es into place with the brick retainer down and toward the outside of the appliance. Slide the top row of
bricks into place to support the baffl e. The baffl e must sit fl at on the outside row of bricks as well as the fl ange on the manifold
shield. Push the baffl e all the way to the rear of the fi rebox, leaving a minimum of 1" (25mm) gap along the front. This will allow
fl ue gases to escape the fi rebox.
E.
Install the remaining bricks along the front opening, as illustrated below.
NOTE: Do not operate if baffl e and manifold shield are not in position.
FIREBRICK
DIMENSIONS
4 1/2" x 9"
A
(114mm x 229mm)
3" x 9" (Molded)
B
(6mm x 229mm)
C
N / A
3" x 9"
D
(76mm x 229mm)
TO VIEW A VIDEO OF THIS INSTALLATION VISIT OUR WEBSITE AT: www.napoleonfi replaces.com/productsupport/s4
NOTE: FOR MORE DETAILED INSTRUCTIONS REFER TO YOUR INSTALLATION MANUAL.
!
FIREBRICK
PART #
DIMENSIONS
W090-0001
4 1/2" x 9"(Notched)
E
X18
(114mm x 229mm)
W090-0002
4 1/2" x 9"(Notched)
F
X2
(114mm x 229mm)
G
N / A
(57mm x 229mm)
W090-0166
1 3/4" x 4 3/4"
H
X2
(64mm x 121mm)
NOTE: All fi rebricks are 1 1/4" (32mm) thick.
A
A
A
A
A
A
A
A
A
G
B
B
WARNING
!
PART #
W090-0207
X1
W090-0208
X1
2 1/4" x 9"
W090-0018
X1
W090-0216
X1
RETAINERS
E
F
A
A
A
A
D
D
A
K
I
J
K
A
K
H
FIREBRICK
DIMENSIONS
2 1/2" x 4 1/2"
I
(64mm x 114mm)
1 1/2" x 4 1/2"
J
(38mm x 114mm)
4 1/2" x 8 1/2"
K
(114mm x 216mm)
BRICK
(Fibre Baffles)
W018-0078 X2
A
A
A
PART #
W090-0016
X1
W090-0017
X1
W090-0210
X3
02.06.14

Publicité

loading

Sommaire des Matières pour Napoleon S4

  • Page 1 (64mm x 121mm) NOTE: All fi rebricks are 1 1/4” (32mm) thick. BRICK RETAINERS (Fibre Baffles) W018-0078 X2 TO VIEW A VIDEO OF THIS INSTALLATION VISIT OUR WEBSITE AT: www.napoleonfi replaces.com/productsupport/s4 NOTE: FOR MORE DETAILED INSTRUCTIONS REFER TO YOUR INSTALLATION MANUAL. 02.06.14...
  • Page 2 NOTE: Tous les briques réfractaires sont de 1 ¼ pouces (32mm) d’épaisseur. SUPPORTS À BRIQUES (Déflecteur en Fibre) W018-0078 X2 POUR REGARDER UNE VIDÉO DE CETTE INSTALLATION VISITER NOTRE SITE WEB: www.napoleonfi replaces.com/productsupport/s4 NOTE: VOIR LE MANUEL D’INSTRUCTIONS D’INSTALLATION POUR LES INSTRUCTIONS PLUS DÉTAILLÉES 02.06.14...