4.2.2. AC voltage
Display range
60 V
600 V
Note : The display indicates " OL " above 630V (900V in peak mode - ONLY
MX 355). Above 630V RMS, a repetitive beep indicates that the voltage being
measured is greater than the safety voltage for which the device is guaranteed.
The display indicates "OL".
4.2.3. DC current
Display range
60 A
400 A
4.2.4. AC current
MX 350
Display range
60 A
400 A
MX 355
Display range
60 A
400 A
Note : The display indicates " OL " above 420A (600A in peak mode –
ONLY MX 355). Above 420A RMS, a repetitive beep indicates that the
current being measured is greater than the safety current for which
the device is guaranteed. The display indicates "OL".
4.2.5. Resistance
Display range
600 Ω
4.2.6. Continuity
Detection threshold
4.2.7. Frequency (for current)
Display
range
600 Hz
20.0 – 600.0 Hz
6 kHz
0.600 – 6.000 kHz
10 kHz
6 – 10 kHz
Range
0.05 – 60.00 V
60.0 – 600.0 V
(only MX 355)
Range
0.10 – 60.00 A
60.0 – 400.0 A
Range
0.05 – 60.00 A
60.0 – 400.0 A
Range
0.05 – 60.00 A
60.0 – 400.0 A
Range
0.2 – 600.0 Ω
(only MX 350)
Range
0.1 Hz
0.001 kHz
0.01 kHz
Frequency
48 – 65 Hz
65 – 400 Hz
48 – 65 Hz
65 – 400 Hz
Resolution
0.01 A
0.1 A
Frequency
Resol
48 – 65 Hz
0.01 A
65 – 400 Hz
48 – 65 Hz
0.1A
65 – 400 Hz
Frequency
Resol
48 – 65 Hz
0.01 A
65 – 400 Hz
48 – 65 Hz
0.1A
65 – 400 Hz
Resolution
0.1 Ω
≤ 35 Ω typical
Resol
0. 2%R + 2 ct
0.2%R + 2 ct
Resol
Accuracy
1.9%R + 5 ct
0.01 V
3.8%R + 5 ct
1.9%R + 5 ct
0.1 V
3.8%R + 5 ct
Accuracy
2.5%R + 10 ct
Accuracy
1.9%R + 5 ct
3.8%R + 5 ct
1.9%R + 5 ct
3.8%R + 5 ct
Accuracy
1.9%R + 5 ct
3.8%R + 5 ct
1.9%R + 5 ct
3.8%R + 5 ct
Accuracy
1%R+ 2ct
Accuracy
Sensibility
3 Arms
3 Arms
26