While the
displayed. The last value measured becomes the
reference value that will be subtracted from subsequent
measurements. Press the
the mode.
Pressing the
deactivate this function, press the
The "peak" function is used for measuring 1 ms peak
value in voltage or current. A long press (2 seconds) on
the
long press deactivates the function.
The clamp switches off automatically after 20 minutes if no
operation is performed. After Autoshutdown, it can be
turned on by switching to any range, or pressing the
button. It is possible to deactivate this function by
holding down the
clamp.
4. TECHNICAL SPECIFICATIONS
Temperature
Freq. For AC signal
Pure AC signal
Electric field
Magnetic field
An overshoot of the range is indicated by
the display unit and by an audible signal.
4.2.1. DC voltage
Display range
60 V
600 V
Zero mode/"Delta" function
(only MX 355)
button is pressed, the ∆ symbol is
Storage
button freezes the value displayed. To
« Peak » function
(only MX 355)
button activates the "peak" function. A second
Autoshutdown
Reference conditions
Specifications
Range
0.03 – 60.00 V
60.0 – 600.0 V
button again to exit from
button before powering up the
+ 23 °C ± 5 °C.
45-65 Hz
< 40 V/m
<1 V/m
Resolution
0.01 V
0.1 V
button again.
Accuracy
1%R + 3 ct
on
25