Rating Plate Information - Napoleon B46NTR Instructions D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8
8
2.4

RATING PLATE INFORMATION

2.4
RATING PLATE INFORMATION
1
EN
EN
DIRECT VENT GAS FIREPLACE. SUITABLE FOR BEDROOM, BATHROOM AND BED-SITTING ROOM
INSTALLATION.
ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED
MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME
CONTRUCTION AND SAFETY STANDARD, TITLE
STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR
MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A.
D
USE WITH BARRIER W565-0228. FOLLOW THE INSTALLATION INSTRUCTIONS LOCATED IN THE
INSTALLATION MANUAL.
A
NOT FOR USE WITH SOLID FUEL.
CERTIFIED WITH THIS UNIT ONLY.
C
WARNING:
ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE FLAMES,
OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE. MINIMUM CLEARANCE
TO COMBUSTIBLE MATERIALS /
DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
TOP/ DESSUS
FLOOR / PLANCHER
SIDES / COTES
BACK / ARRIERE
MANTEL / MANTEAU
* MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 2". SEE INSTRUCTION
MANUAL FOR GREATER EXTENSIONS. REFERER AU MANUEL D'INSTRUCTION POUR DES
EXTENSIONS PLUS GRANDES.
SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUM AND MAXIMUM VENT LENGTHS.
REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR LES LONGUEURS
D'EVACUATION MINIMALE ET MAXIMALE.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
B
For rating plate location, see "INSTALLATION OVERVIEW" section.
For rating plate location, see "INSTALLATION OVERVIEW" section.
MATERIAL: .010 VELVET MATTE LEXAN AND/OR .050 HI-TEMP POLYESTER
MIN. LETTERING FOR "NOT FOR USE WITH SOLID FUEL. ", "UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CELUI. " TO BE 10 POINT ARIAL, BOLD FACE,
UPPER CASE AND 2 POINT LEADING SPACING OR EQUIVALENT. HOLE TO BE 0.250" Ø.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
BLACK ON WHITE BACKGROUND
MAX OVERALL DECAL SIZE: 4.75" x 8.50"
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
HOLE IS 0.250"
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
SERIAL NUMBERS TO BE ASCENDING FROM
A barrier designed to reduce the risk of burns from the hot viewing glass, it is provided with the
A barrier designed to reduce the risk of burns from the hot viewing glass, it is provided with the
A
appliance and shall be installed.
appliance and shall be installed.
This drawing is the property of Wolf Steel LTD. or NAC.
It is not to be reproduced nor used in any manner
without our consent. All rights are reserved.
1
W415-1613 / C / 12.22.16
W415-1613 / D / 09.20.17
2
CONFORMS TO / CONFORME AUX: ANSI Z21.50-2014, CERTIFIED TO / CERTIFIE CSA 2.22-2014 VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ.
SUITABLE
FOR
MOBILE
HOME
INSTALLATION
24 CFR, PART 3280. WHEN THIS US
B46NTR
B46NTRE
0-4500FT (0-1370m)
22,000 BTU/h
17,500 BTU/h
MANIFOLD PRESSURE: 3.5" (9MB) WATER COLUMN
PRESSION AU COLLECTEUR: 3.5" (9 MB) D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE: 4.5" (11MB) WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE: 4.5" (11MB) D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE: 13.0" (32MB) WATER COLUMN
PRESSION D'ALIMENTATION MAXIMALE: 13.0" (32MB) D'UNE COLONNE D'EAU
FOR USE WITH GLASS DOORS
THIS FIREPLACE USES AND REQUIRES A FAST ACTING THERMOCOUPLE. REPLACE
0
RECESSED DEPTH / PROFONDEUR D'ENCASTRE
0
VENT SIDES / COTES DE L'EVENT
0
VENT TOP / EVENT SUPERIEUR
0
VENT BOTTOM / EVENT INFERIEUR
2" *
Ø
/ 0.312 "FROM BOTTOM AND LEFT EDGE"
B46TR 007160
TOLERANCES:
2
3
FOYER À GAZ VENTILÉ DIRECT. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER,
IF
INSTALLED
IN
UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI
SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE MAISONS
MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE
ET DE CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU
CETTE NORME D'ETATS-UNIS NE PEUT ETRE APPLIQUEE, SE REFERER A LA NORME RELATIVE AU
FOR
CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES
MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A.
9700539 (WSL)
4001657 (NGZ)
4001658 (NAC)
4001659 (WUSA)
CB46NTR
MODEL
CB46PTR
CB46NTRE
CB46PTRE
ALTITUDE / ELEVATION
0-4500FT (0-1370m)
INPUT / ALIMENTATION
22,000 BTU/h
REDUCED INPUT / ALIMENTATION REDUITE
19,000 BTU/h
MANIFOLD PRESSURE: 10" (25MB) WATER COLUMN
PRESSION AU COLLECTEUR: 10" (25MB) D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE: 11" (27MB) WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE: 11" (27MB) D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE: 13" (32MB) WATER COLUMN
PRESSION D'ALIMENTATION MAXIMALE: 13" (32MB) D'UNE COLONNE D'EAU
P4: 65%
P4: 65%
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC
CET APPAREIL.
HOMOLOGUEES SEULEMENT AVEC CETTE UNITE.
AVERTISSEMENT:
CE FOYER UTILISE ET REQUIERT UN THERMOCOUPLE À ACTION RAPIDE.
REMPLACEZ UNIQUEMENT AVEC UN THERMOCOUPLE À ACTION RAPIDE DE WOLF STEEL LTÉE.
N'AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES
AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
18"
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE WOLF STEEL VENT KITS. SEE OWNERS
1"
INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING IS
3"
NECESSARY AFTER SERVICING THE VENT-AIR INTAKE SYSTEM.
1"
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A NAPOLEON.
REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. IL EST
IMPORTANT DE BIEN REINSTALLER ET RESCELLER L'EVENT APRES AVOIR ASSURE LE MAINTIEN DU
SYSTEME DE PRISE D'AIR.
DECORATIVE PRODUCT: NOT FOR USE AS A HEATING APPLIANCE
PRODUIT DÉCORATIF: NE PAS UTILISER COMME APPPAREIL DE CHAUFFAGE.
ELECTRICAL RATING / CLASSIFICATION: 115V 0.82AMP, 60HZ
OPTIONAL FAN KIT / ENSEMBLE DE VENTILATEUR FACULTATIF: EP35
SERIAL NUMBER/NO. DE SERIE:
RATING PLATE
.010 VELVET MATTE LEXAN AND/OR .050 HI-TEMP POLYESTER
A
UPDATED MAX. SUPPLY PRESSURE (NG)
MM/DD/YY: 03.21.16
3
4
POUR UNE UTILISER
AVEC BARRIÈRE W565-0228. SUIVEZ LES INSTRUCTIONS D'INSTALLATION SE
TROUVENT DANS LE MANUEL D'INSTALLATION.
B46PTR
B46PTRE
UTILISER AVEC LES PORTES VITREES
B46TR
B46(N)TR(E) / B46(P)TR(E)
4
REV.
W385-2134
A
5
D
C
W385-2134 / A
B
Page 1 of 2
A
W385-2134_A
03.21.18_JK
MM/DD/YY: 04.01.16
JFK
5

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

B46ntreB46ptrB46ptre

Table des Matières