ACCESS TO MENUS
Press the OK key
OK
BFT
Control unit software version
LIBRA c ma
No. total manoeuvres
OK
(in thousands)
0000
No. manoeuvres since latest
0000
maintenance(in thousands)
00
No. radio control devices
memorised
PARAM
+/-
END
- +
LOGIC.
+/-
END
- +
FOLLOWING MENUS
FIG. B
16 - LIBRA-C-MA - Ver. 04
[ 00 ]
/ON
/OFF
OK
- +
+/-
OK
TCA
- +
m1 t
- +
m2 t
- +
m1 t slow
- +
m2 t slow
- +
open delay time
- +
cls delay time
- +
m1 fast time
- +
m2 fast time
- +
slov speed
- +
zone
+/-
[oFF]
OK
TCA
OK
- +
[off]
3 step
OK
- +
[off]
ibl open
OK
- +
[off]
fast cls
OK
- +
[off]
OK
photoc. open
- +
[off]
OK
TEST PHOT
- +
[off]
OK
SCA 2ch
- +
[off]
OK
i Mot ON
- +
[off]
OK
BLOC persist
- +
[off]
OK
hold-to-run
- +
[off]
OK
fixed code
- +
[on]
OK
radio prog
- +
[off]
OK
master
- +
[off]
OK
start open
- +
[off]
OK
pre-alarm
- +
[on]
OK
auto fast time
Fig. A
+
8888
OK
Preset value
Parameter increment/reduction
or ON/OFF commutation
Press OK key (Enter/confirm)
Menu scrolling
(+ = preceding - = following)
[0010]
OK
OK
[0050]
OK
OK
[0050]
OK
OK
[0045]
OK
OK
[0045]
OK
OK
[1. 0 ]
OK
OK
[1. 0 ]
OK
OK
[15. 0 ]
OK
OK
[15. 0 ]
OK
OK
[50]
OK
OK
[0000]
OK
OK
ON
OK
PRG
OFF
ON
OK
PRG
OFF
ON
OK
PRG
OFF
ON
OK
PRG
OFF
ON
OK
PRG
OFF
ON
OK
PRG
OFF
ON
OK
PRG
OFF
ON
OK
PRG
OFF
ON
OK
PRG
OFF
ON
OK
PRG
OFF
ON
OK
PRG
OFF
ON
OK
PRG
OFF
ON
OK
PRG
OFF
ON
OK
PRG
OFF
ON
OK
PRG
OFF
ON
OK
PRG
OFF
LEGENDA
+/-
Simultaneously press the + and - keys.
Simultaneous pressure of the + and – keys
allows you to exit the active menu and return
to the preceding menu; if this takes place at
the main menu level, programming is exited
and the display switched off.
The modifications made are only confirmed if
the OK key is subsequently pressed.
Message: Programming in progress
PRG
Message: KO! (value or function error)
Message: "Wait" (enter value or function)
PRG
PARAMETER MENU
TCA (automatic closing time)
PRG
value expressed in seconds
(default 10=10s, min 3=3s, max 120=120s)
Motor 1 torque value expressed in %
PRG
(default 50%, min 1%, max 99%)
Motor 2 torque value expressed in %
(default 50%, min 1%, max 99%)
PRG
Motor 1 torque slow-down
value expressed in %
(default 45%, min 1%, max 99%)
PRG
Motor 2 torque slow-down
value expressed in %
(default 45%, min 1%, max 99%)
PRG
Opening phase-difference Time
value expressed in tenths of a second
(default 10=1s, min 10=1s, max 100=10s)
PRG
Closing phase-difference Time
value expressed in tenths of a second
PRG
(default 10=1s, min 10=1s, max 250=25s)
Motor 1 fast time
value expressed in seconds
(default 15=15s, min 1=1s, max 30=30s)
PRG
Motor 2 fast time
value expressed in seconds
(default 15=15s, min 1=1s, max 30=30s)
PRG
Slow-down speed
value expressed in %
PRG
0= Slow-down disabled
(default 50%, min 0%, max 99%)
Zone numerical value
(default 0, min 0, max 127)