3. Mounting the detector

1.
Lift off the custom insert and remove the enclosed screw (fig.
steps 1 and 2).
2.
Using a screwdriver, carefully prise open the detector (fig.
and 4).
3.
Remove the interior part (fig.
4.
Fix the base to the wall between 1.8 m and 3.0 m (5.9-9.8 ft.) from the
floor. For flat-mounting use a minimum of two screws (DIN 7998), at
least one in position A and one in position B. For corner-mounting use
screws in positions C or D (fig.
CAUTION! Not all screw positions have pry-off tamper. Non
pry-off positions are shown in the Warning box in figure
5.
Wire the detector (figs.
6.
Select the desired jumper and DIP switch settings (Section 4).
Replace the interior part (fig. b).
7.
Align the detector, as shown (figs. c and
8.
beam and walk testing the detector (section 6).
Remove the blinders and add the stickers, if required (see figs. d and
9.
e for an example).
10. Insert the insect-protection caps (fig. f, step 1).
11. Close the cover (fig. f, step 2).
12. Insert the screw (if required) and replace the custom insert (fig. f,
step 3).

4. Setting the detector

The detector must be restarted (re-powered) after changing the settings or
detection pattern.
Jumpers (fig.
J1 : PIR sensitivity
It changes the distance-to-alarm delay (the speed of the decision
algorithm); the higher the sensitivity, the faster the sensor will react
(fig.
). There are three different PIR sensitivities.
).
and
)
- 9 -
).
).
j
) and see Aligning the
J1
,
, steps 3
.
J2
J3