28

5.2.1 ALCOVE CLEARANCE TO COMBUSTIBLES ENCLOSURE

EN
78"
[198cm]
ENCLOSURE
HEIGHT
* See venting section.
IMPORTANT: THE FIRESTOP ASSEMBLY PROVIDED MUST BE USED WHEN THE VENT PIPES PASS
THROUGH ANY COMBUSTIBLE WALL, FLOOR OR CEILING.
NOTE: THE MINIMUM ENCLOSURE VOLUME MUST BE INCREASED BY NO LESS THAN THE VOLUME OF
THE RECESS. THIS ADJUSTMENT CAN BE MADE BY INCREASING ANY OR ALL OF THE HEIGHT, WIDTH,
AND DEPTH OF THE ENCLOSURE.
W415-1519 / H / 03.22.17
COMBUSTIBLE
NON-COMBUSTIBLE
MATERIAL
4 1/2"
[114mm]
7 1/2"
[191mm]
59 1/2"
[151.1cm]
CEILING
42 3/8"
[107.6cm]
34 7/8"
[88.6cm]
COMBUSTIBLE
MYLAR
SLEEVE
MAX.
STEEL STUD
FRAME
COMBUSTIBLE
MYLAR
NON-COMBUSTIBLE
BRICK
3"
[76mm]
0" (0MM) IF
NON-COMBUSTIBLE
FINISHING MATERIAL
IS USED SUCH AS
BRICK AND STONE
2"
[51mm]
FIRESTOP
ASSEMBLY
49 3/4"
[126.4cm]
MINIMUM
PLUS RISE *
1" [25mm]
NON-COMBUSTIBLE
BRICK
0" (0MM) IF
3"
NON-COMBUSTIBLE
[76mm]
FINISHING MATERIAL
IS USED SUCH AS
BRICK AND STONE