10.5
BLOWER REPLACEMENT
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH
THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS
COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL
ENSURE THAT THE FAN'S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE
APPLIANCE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE. DO NOT RUN THE POWER
THE WIRE HARNESS PROVIDED IN THE BLOWER KIT IS A UNIVERSAL HARNESS. WHEN
INSTALLED, ENSURE THAT ANY EXCESS WIRE IS CONTAINED, PREVENTING IT FROM MAKING
This appliance comes equipped with a blower, a heat sensor, variable on/off speed control and a power cord.
The blower is thermally activated, so when it is turned on, it will automatically start approximately 15 minutes
after lighting the appliance and will run for approximately 30 minutes after the appliance has been turned
off. Use of the fan increases the output of heat. Air, drawn in
through the lower louvre access door, is driven up the back of
the firebox, and exhausted as hot air between the upper louvres.
A.
Open the lower control area.
B.
Remove the control panel (3 screws).
C.
Unplug the blower from the junction box or turn off
the power to the appliance if hard wired.
D.
Undo the fastener at the left side of the blower
mounting plate. The blower should now slide to the
left, away from the mounting tab.
E.
Finally, disconnect the slip-on connectors at the
motor of the blower.
Drywall dust will penetrate into the blower bearings,
causing irreparable damage. Care must be taken to prevent
drywall dust from coming into contact with the blower or its
compartment. Any damage resulting from this condition is not covered by the warranty policy.
11.0 REPLACEMENTS
FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE
ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY
Contact your dealer for questions concerning prices and policies on replacement parts. Normally, all parts
** THIS IS A FAST ACTING THERMOCOUPLE. IT IS AN INTEGRAL SAFETY COMPONENT. REPLACE ONLY WITH
can be ordered through your Authorized dealer / distributor.
FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE
REQUIRED TO HONOUR THE CLAIM.
When ordering replacement parts always give the following information:
•
Model & Serial Number of appliance
•
Installation date of appliance
•
Part number
•
Description of part
•
Finish
PARTS, PART NUMBERS AND AVAILABILITY ARE SUBJECT TO CHANGE WITHOUT NOTICE.
PARTS IDENTIFIED AS STOCKED WILL BE DELIVERED WITHIN 2 TO 5 BUSINESS DAYS FOR MOST
DELIVERY DESTINATIONS.
PARTS NOT IDENTIFIED AS STOCKED WILL BE DELIVERED WITHIN A 2 TO 4 WEEK PERIOD, FOR
MOST CASES.
PARTS IDENTIFIED AS 'SO' ARE SPECIAL ORDER AND CAN TAKE UP TO 90 DAYS FOR DELIVERY.
!
RISK OF FIRE AND ELECTRICAL SHOCK.
VOID THE WARRANTY AND CERTIFICATION.
CORD BENEATH THE APPLIANCE.
CONTACT WITH MOVING OR HOT OBJECTS.
DAMAGE OR PERSONAL INJURY.
A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
WARNING
G
B
VARIABLE SPEED SWITCH
W
BLOWER REPLACEMENT
B
A
WARNING
!
45
51.5
HEAT SENSOR
FAN
C
41.1C
W415-1519 / H / 03.22.17
EN