INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE
CONFORMS TO AMERICAN NATIONAL STANDARDS: ANSI Z21.50, CERTIFIED TO CANADIAN CSA 2.22 FOR VENTED GAS FIREPLACES.
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
SAFETY INFORMATION
WARNING
!
If the information in these instructions
are not followed exactly, a fi re or
explosion may result causing property
damage, personal injury or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certifi ed kit is used.
Decorative Product: Not for use as a heating appliance.
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • hearth@napoleonproducts.com
$10.00
INSTALLATION AND
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
GX70NT & GX70NTE
NATURAL GAS MODEL
GX70PT & GX70PTE
PROPANE GAS MODEL
DANGER
!
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and shall be installed for the protection of children
and other at-risk individuals.
BARRIER
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
1.28F
W415-1519 / C / 11.06.15
EN
FR
PG
65

Publicité

loading

Sommaire des Matières pour Napoleon GX70NT

  • Page 1 BARRIER Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • hearth@napoleonproducts.com $10.00...
  • Page 2 DOOR GLASS REPLACEMENT 10.3 BLOWER REPLACEMENT 11.0 GX70 OVERVIEW 12.0 GX70NT/PT MILLIVOLT VALVE TRAIN ASSEMBLY 13.0 GX70NTE/PTE ELECTRONIC VALVE TRAIN ASSEMBLY 14.0 GX70 ACCESSORIES NOTE: Changes, other than editorial, are denoted by a vertical line in the margin. W415-1519 / C / 11.06.15...
  • Page 3 1.0 INSTALLATION OVERVIEW See the section “MINIMUM ENCLOSURE CLEARANCES” for drywall (or other combustible material). See the section “VENTING” and “INSTALLATION”. See the section “MINIMUM MANTEL CLEARANCES” See the section “FRAMING” See the section See the section “FRAMING - MINIMUM “NON-COMBUSTIBLE CLEARANCE TO FINISHING”.
  • Page 4 2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • ANY CHANGES TO THIS APPLIANCE OR IT’S CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. • Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fi...
  • Page 5 GX70 DIMENSIONS 11 13/16" 299mm 5" 34 5/8” 34 5/8" 127mm 879mm 879mm 8" SAFETY BARRIER 203mm 7 3/16" 11 5/16" 182mm 288mm INLET 18 1/2" 470mm GX70 ILLUSTRATED 1 15/16" 35" 50mm 890mm W415-1519 / C / 11.06.15...
  • Page 6 GENERAL INSTRUCTIONS WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT, WITH THE GLASS DOOR OPENED OR REMOVED. PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE. PROVIDE ADEQUATE VENTILATION. NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48”...
  • Page 7 GENERAL INFORMATION FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY! RATES AND EFFICIENCIES GX70 Altitude (FT) 0-4,500 0-4500 Max. Input (BTU/HR) 35,000 32,000 Min. Inlet Gas Supply Pressure 4.5" (11mb) w.c. 11" (27mb) w.c. Max.
  • Page 8 VENT BOTTOM / EVENT INFERIEUR BOTTOM / EVENT INFERIEUR BOTTOM / EVENT INFERIEUR 2" L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A NAPOLEON. MANTEL / MANTEAU 10 1/2 ” REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. IL EST * MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 2".
  • Page 9 3.0 VENTING WARNING RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE. IF VENTING IS INCLUDED WITH SPACERS THE VENT SYSTEM MUST BE SUPPORTED EVERY 3FT (0.9m) FOR BOTH VERTICAL AND HORIZONTAL RUNS. USE SUPPORTS OR EQUIVALENT NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROM COMBUSTIBLES.
  • Page 10 VENTING LENGTHS AND COMPONENTS FOR DIRECT VENT INSTALLATIONS Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or Metal-Fab venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air terminal locations for either system are set out in this manual and must be adhered to. For Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent and Metal-Fab follow the installation procedure provided with the venting components.
  • Page 11 TYPICAL VENT INSTALLATION 16" (406MM) MINIMUM 40 FT (12M) WARNING! MAXIMUM 3 FT (1M) THE FIRST TWO FEET OF OUTER 8” (203MM) MINIMUM DIAMETER VENT PIPE FROM THE APPLIANCE MUST BE WRAPPED IN THE 1” (25MM) THICK INSULATION SLEEVE (SUPPLIED). 34 5/8"...
  • Page 12 SPECIAL VENT INSTALLATIONS 18" (610MM) MAXIMUM 15 1/8" (384MM) WARNING! MINIMUM THE FIRST TWO FEET OF OUTER 8” (178MM) 48 1/4" DIAMETER VENT PIPE FROM (1226MM) THE APPLIANCE MUST BE 34 5/8" MINIMUM WRAPPED IN THE 1” (25MM) (879MM) PLUS RISE* THICK INSULATION SLEEVE (SUPPLIED).
  • Page 13 MINIMUM AIR TERMINAL LOCATION CLEARANCES COVERED BALCONY APPLICATIONS ††* = 3 feet = 2 x ACTUAL (0.9m) (4.6m) INSTALLATIONS CANADA U.S.A. 12” (305mm) 12” (305mm) Clearance above grade, veranda porch, deck or balcony. 9” 12” (305mm) Clearance to windows or doors that open. Δ...
  • Page 14 VENTING APPLICATION FLOW CHART TOP EXIT Horizontal Termination Vertical Termination Vertical rise is equal Vertical rise is equal Vertical rise is less Vertical rise is less to or greater than to or greater than than horizontal run than horizontal run the horizontal run the horizontal run Horizontal run +...
  • Page 15 TOP EXIT HORIZONTAL TERMINATION ) < (V See graph to determine the required vertical Simple venting confi guration (only one 90° elbow) rise V for the required horizontal run H 40 (12.2) 39 (11.9) REQUIRED 30 (9.1) VERTICAL RISE IN FEET 20 (6.1) (METERS)V 10 (3.1)
  • Page 16 ) > (V Simple venting configuration (only one 90° elbow) See graph to determine the required vertical rise V for the required horizontal run H 150 (3810) 147 (3733.8) REQUIRED VERTICAL RISE 100 (2540) IN INCHES (MILLIMETERS) V 57 (1447.8) 50 (1270) 14 (355.6) 20 (6.1)
  • Page 17 TOP EXIT VERTICAL TERMINATION ) < (V Simple venting configurations. See graph to determine the required vertical rise V for the required horizontal run H 40 (12.2) 30 (9.1) REQUIRED VERTICAL RISE IN FEET 20 (6.1) (METERS) V 10 (3.1) 3 (0.9) (1.5) (3.1)
  • Page 18 ) > (V Simple venting configurations. See graph to determine the required vertical rise V for the required horizontal run H 20 (6.1) 19 (5.8) REQUIRED VERTICAL RISE IN FEET 10 (3.1) (METERS) V 3 (0.9) (7.6) (9.1) (1.5) (3.1) (4.6) (6.1) HORIZONTAL VENT RUN PLUS OFFSET IN FEET (METERS) H...
  • Page 19 4.0 INSTALLATION WARNING ENSURE TO UNPACK ALL LOOSE MATERIALS FROM INSIDE THE FIREBOX PRIOR TO HOOKING UP THE GAS AND ELECTRICAL SUPPLY. IF YOUR APPLIANCE IS SUPPLIED WITH A REMOTE ENSURE THE REMOTE RECEIVER IS IN THE “OFF” POSITION PRIOR TO HOOKING UP THE GAS AND ELECTRICAL SUPPLY TO THE APPLIANCE. FOR SAFE AND PROPER OPERATION OF THE APPLIANCE, FOLLOW THE VENTING INSTRUCTIONS EXACTLY.
  • Page 20 4.1.1 HORIZONTAL INSTALLATION WARNING THE FIRESTOP ASSEMBLY MUST BE INSTALLED WITH THE VENT SHIELD TO THE TOP. TERMINALS MUST NOT BE RECESSED INTO A WALL OR SIDING MORE THAN THE DEPTH OF THE RETURN FLANGE OF THE MOUNTING PLATE. This application occurs when venting through an exterior wall. Having determined the correct height for the air terminal VENT location, cut and frame a hole in the exterior wall as...
  • Page 21 USING FLEXIBLE VENT COMPONENTS WARNING DO NOT ALLOW THE INNER FLEX PIPE TO BUNCH UP ON HORIZONTAL OR VERTICAL RUNS AND ELBOWS. KEEP IT PULLED TIGHT. SPACERS ARE ATTACHED TO THE INNER FLEX PIPE AT PREDETERMINED INTERVALS TO MAINTAIN AN EVEN AIR GAP TO THE OUTER FLEX PIPE.
  • Page 22 4.2.2 VERTICAL AIR TERMINAL INSTALLATION WARNING MAINTAIN A MINIMUM 2” (51mm) SPACE BETWEEN THE AIR INLET BASE AND THE STORM COLLAR. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
  • Page 23 4.2.3 APPLIANCE VENT CONNECTION Install the inner exhaust fl ue collar to the appliance. Secure #8 X 1/2” with 3 screws. Seal the joint and screw holes using the high SELF temperature sealant Mill-Pac W573-0007 (not supplied). DRILLING SCREWS Install the outer fl ex pipe to the appliance. Attach and seal the 2”...
  • Page 24 4.3.2 VERTICAL AIR TERMINAL INSTALLATION Move the appliance into position. INNER PIPE Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
  • Page 25 MOBILE HOME INSTALLATION This appliance is also certifi ed to be installed as an OEM (Original Equipment Manufacturer) installation in a manufactured home (U.S. only) or mobile home and must be installed in accordance with the manufacturer’s instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada.
  • Page 26 GAS INSTALLATION WARNING RISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH AS SPARKS OR OPEN FLAMES. SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 27 5.0 FRAMING WARNING RISK OF FIRE! IN ORDER TO AVOID THE POSSIBILITY OF EXPOSED INSULATION OR VAPOUR BARRIER COMING IN CONTACT WITH THE APPLIANCE BODY, IT IS RECOMMENDED THAT THE WALLS OF THE APPLIANCE ENCLOSURE BE “FINISHED” (IE: DRYWALL / SHEETROCK), AS YOU WOULD FINISH ANY OTHER OUTSIDE WALL OF A HOME.
  • Page 28 MINIMUM FRAMING DIMENSIONS 39 5/8" [1006mm] 34 5/8" [879mm] 1 15/16"[49mm] 18 9/16" 471mm * Based on a 1/2" fi nishing material W415-1519 / C / 11.06.15...
  • Page 29 It is best to frame your appliance after it is positioned and the vent system is installed. Frame to local building codes. It is not necessary to install a hearth extension with this appliance. When roughing in the appliance, raise the appliance to accommodate for the thickness of the fi nished fl oor materials, i.e.
  • Page 30 MINIMUM ENCLOSURE CLEARANCES COMBUSTIBLE NON-COMBUSTIBLE BRICK 3" 76mm 0” (0MM) IF NON-COMBUSTIBLE FINISHING MATERIAL IS USED SUCH AS BRICK AND STONE. NON-COMBUSTIBLE MYLAR MATERIAL SLEEVE 2" 51mm 6 3/4" [883mm] FIRESTOP ASSEMBLY 78" 1981mm STEEL STUD CEILING FRAME (MIN) 59 1/2" 48 1/4"...
  • Page 31 5.2.1 ALCOVE CLEARANCE TO COMBUSTIBLES ENCLOSURE 3" 76mm 0” (0MM) IF NON-COMBUSTIBLE FINISHING MATERIAL IS USED SUCH AS MYLAR COMBUSTIBLE SLEEVE BRICK AND STONE 4 1/2" 114mm NON-COMBUSTIBLE MATERIAL 2" 51mm 7.5" 59 1/2" 191mm FIRESTOP 1511mm ASSEMBLY CEILING 78" STEEL STUD 1981mm FRAME...
  • Page 32 RECESSED INSTALLATION WARNING INSTALLING A TELEVISION ABOVE A FIREPLACE MAY CAUSE DISCOLOURATION, MELT OR DAMAGE THE ELECTRONIC DEVICE. USE THE INDICATED CLEARANCE AND REFER TO THE INSTRUCTIONS OF YOUR MANUFACTURER FOR FURTHER INFORMATION . WARNING: Non-combustible facing materials must not project more than 4" (102mm) from the face of the door (all three sides).
  • Page 33 NON-COMBUSTIBLE FACING MATERIAL WARNING: Non-combustible facing material must not project more than 4” (102mm) from the face of the door (all three sides). If greater projections are desired, increase the clearance to the sides and top by 2” (51mm) for every additional 1” (25mm) of projection. If using an optional surround, the same rule applies, starting from the top of the surround.
  • Page 34 MINIMUM COMBUSTIBLE MANTEL CLEARANCES WARNING RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE CLEARLY MAINTAINED.
  • Page 35 6.0 FINISHING WARNING RISK OF FIRE! NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS SUCH AS BRICK, MARBLE, GRANITE, ETC., PROVIDED THAT THESE MATERIALS DO NOT GO BELOW THE SPECIFIED DIMENSION AS ILLUSTRATED. DO NOT STRIKE, SLAM OR SCRATCH GLASS.
  • Page 36 SAFETY SCREEN / DOOR REMOVAL AND INSTALLATION WARNING GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED. THE DOOR LATCHES ARE PART OF A SAFETY RELIEF SYSTEM AND MUST BE PROPERLY ENGAGED. DO NOT OPERATE THE APPLIANCE WITH LATCHES DISENGAGED. FACING AND/OR FINISHING MATERIALS MUST NOT INTERFERE WITH AIR FLOW THROUGH AIR OPENINGS, LOUVRES OPENINGS, OPERATION OF LOUVRES OR DOORS OR ACCESS FOR SERVICE.
  • Page 37 LOG PLACEMENT WARNING FAILURE TO POSITION THE LOGS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY LOGS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY. LOGS MUST BE PLACED IN THEIR EXACT LOCATION IN THE APPLIANCE. DO NOT MODIFY THE PROPER LOG POSITIONS, SINCE APPLIANCE MAY NOT FUNCTION PROPERLY AND DELAYED IGNITION MAY OCCUR.
  • Page 38 Place the end of log #5 on the left end of Place log #6 along the back edge of the grate log #1 and on the pin of log #2. wrapping around the 3rd grate post. Ensure logs do not cover any ports. GLOWING EMBERS Tear the embers into pieces and place along the front row of ports covering all of the burner area in front of the small logs.
  • Page 39 WIRING DIAGRAM (ELECTRONIC) WARNING DO NOT WIRE 110 VOLTS TO THE VALVE OR WALL SWITCH. NIGHT BLOWER LIGHT NOTE: This appliance is equipped with a three-prong (grounding) plug for protection against shock hazard and should be connected into a properly grounded circuit. Do not cut or remove the grounding prong from the plug.
  • Page 40 7.0 OPERATION GX70NT & GX70PT (MILLIVOLT) WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 41 GX70NTE & GX70PTE (ELECTRONIC) WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 42 GENERAL TRANSMITTER LAYOUT (ELECTRONIC ONLY) Key Lock Low Battery Alarm Low battery alarm Transmission Room Temperature CPI mode Flame ON LED Light Blower (NOT AVAILABLE WITH THIS MODEL) INITIALIZING THE TRANSMITTER/BATTERY HOLDER FOR THE FIRST TIME Install the 4 AA batteries into the Profl ame 2 battery holder, note the polarity of the batteries and insert as indicated on the cover (+/-).
  • Page 43 TEMPERATURE DISPLAY With the system in the “OFF” position, press the Temperature Key and the Mode Key at the same °F °C time to change from degrees F to C. Look at the LCD screen on the Transmitter to verify that a C or F is visible to the right of the Room Temperature display.
  • Page 44 NIGHT LIGHT DIMMER CONTROL The auxiliary function controls the Night Light with °F °F dimmable control. Use the Mode Key to guide you to the Night Light icon. The intensity of the output can be adjusted through 6 levels. Use the UP/DOWN arrow keys to adjust the output level.
  • Page 45 7.12 BATTERY HOLDER/BACKUP INSTALLATION (ELECTRONIC ONLY) The battery holder is located in the valve compartment accessible for programming the remote. Install 4 AA batteries, ensure that the positive and negative ends correspond with those identifi ed in the battery holder. In the case of a power outage the 3 position slider switch needs to be in the "ON"...
  • Page 46 8.0 ADJUSTMENT PILOT BURNER ADJUSTMENT Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow. Check Pressure Readings: Inlet pressure can be checked by turning screw (A) counter- clockwise 2 or 3 turns and then placing pressure gauge tubing over the test point.
  • Page 47 FLAME CHARACTERISTICS It’s important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the illustration provided. If any fl ames appear abnormal call a service person. PILOT ELECTRODE BURNER 3/8” - 1/2” (9.5mm - 12.7mm) FLAME SENSOR FLAME MUST ENVELOP...
  • Page 48 NEVER ALLOW CHILDREN discoloration and / or blemishes may result. TO TOUCH GLASS. This appliance is factory equipped with 4mm tempered glass. Use only replacement glass available from your Napoleon® dealer. DO NOT SUBSTITUTE MATERIALS. W415-1519 / C / 11.06.15...
  • Page 49 10.0 REPLACEMENTS WARNING FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY. ** THIS IS A FAST ACTING THERMOCOUPLE. IT IS AN INTEGRAL SAFETY COMPONENT. REPLACE ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
  • Page 50 10.2 DOOR GLASS REPLACEMENT WARNING DO NOT USE SUBSTITUTE MATERIALS. GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED. CARE MUST BE TAKEN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR DAMAGED COMPONENTS. BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE APPLIANCE BEFORE OPERATION.
  • Page 51 10.3 BLOWER REPLACEMENT WARNING RISK OF FIRE AND ELECTRICAL SHOCK. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE. USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.
  • Page 52 W415-1519 / C / 11.06.15...
  • Page 53 W415-1519 / C / 11.06.15...
  • Page 54 W415-1519 / C / 11.06.15...
  • Page 55 W415-1519 / C / 11.06.15...
  • Page 56 15.0 TROUBLESHOOTING (ELECTRONIC) WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS.
  • Page 57 SYMPTOM PROBLEM TEST SOLUTION Carbon is being Air shutter has become Ensure air shutter opening is free of lint or other deposited on blocked. obstructions. glass, logs, Flame is impinging on the Check that the glass, logs, rocks or media are rocks, media glass, logs, rocks, media correctly positioned.
  • Page 58 SYMPTOM PROBLEM TEST SOLUTION White / grey fi lm Sulphur from fuel is being Clean the glass, see “CARE OF GLASS” section forms. deposited on glass, logs or DO NOT CLEAN GLASS WHEN HOT. combustion chamber If deposits are not cleaned off regularly, the glass surfaces.
  • Page 59 16.0 TROUBLESHOOTING (MILLIVOLT) WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS.
  • Page 60 SYMPTOM PROBLEM TEST SOLUTION Pilot will not light. No spark at pilot burner. Check if pilot can be lit by a match. Check that the wire is connected to the push button igniter. Check if the push button igniter needs tightening. Replace the wire if the wire insulation is broken or frayed.
  • Page 61 SYMPTOM PROBLEM TEST SOLUTION White / grey fi lm forms. Sulphur from fuel is being Clean the glass with a recommended gas appliance deposited on glass, logs or glass cleaner. combustion chamber surfaces. DO NOT CLEAN GLASS WHEN HOT. If deposits are not cleaned off regularly, the glass may become permanently marked.
  • Page 62 All parts replaced under the President’s Limited Lifetime Warranty Policy are subject to a single claim. During the fi rst 10 years NAPOLEON will replace or repair the defective parts covered by the lifetime warranty at our discretion free of charge. From 10 years to life, NAPOLEON will provide replacement parts at 50% of the current retail price.
  • Page 63 18.0 SERVICE HISTORY 43.1 W415-1519 / C / 11.06.15...
  • Page 64 Fireplace Inserts • Charcoal Grills • Gas Fireplaces • Waterfalls • Wood Stoves Heating & Cooling • Electric Fireplaces • Outdoor Fireplaces • Gourmet Grills 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8...
  • Page 65 à risque. ÉCRAN DE PROTECTION N° de série N° DE MODÈLE Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Téléphone 705-721-1212 • Télécopieur 705-722-6031 • www.napoleonfoyers.com • hearth@napoleonproducts.com 10,00$ 1.28D...
  • Page 66 DISPOSITION DES BÛCHES BRAISES INCANDESCENTES MISE EN PLACE DU LOGO SCHÉMA DE CÂBLAGE (ELECTRONIQUE) FONCTIONNEMENT GX70NT & GX70PT (MILLIVOLT) GX70NTE & GX70PTE (ELECTRONIQUE) DESSIN GÉNÉRAL DE LA TÉLÉCOMMANDE (ÉLECTRONIQUE SEULEMENT) PREMIÈRE INITIALISATION DE LA TÉLÉCOMMANDE/BLOC-PILES AFFICHEUR DE TEMPÉRATURE HAUTEUR DE LA FLAMME...
  • Page 67 1.0 VUE D'ENSEMBLE DE L'INSTALLATION Voir la section « DÉGAGEMENTS MINIMAUX DE L’ENCEINTE » pour les cloisons sèches (ou autre matériau combustible). Voir les sections « ÉVACUATION » et « INSTALLATION ». Voir la section « DÉGAGEMENTS MINIMAUX DE LA TABLETTE ».
  • Page 68 2.0 INTRODUCTION AVERTISSEMENT • CET APPAREIL EST CHAUD LORSQU’IL FONCTIONNE ET PEUT CAUSER DE GRAVES BRÛLURES EN CAS DE CONTACT. • TOUTE MODIFICATION APPORTÉE À CET APPAREIL OU AUX CONTRÔLES PEUT ÊTRE DANGEREUX ET EST INTERDIT. • Ne faites pas fonctionner l’appareil avant d’avoir lu et compris les instructions d’opération. Omettre d’utiliser l’appareil selon les instructions d’opération pourrait causer un incendie ou des blessures.
  • Page 69 GX70 DIMENSIONS 11 13/16" 299mm 5" 34 5/8” 34 5/8" 127mm 879mm 879mm 8" ÉCRAN DE PROTECTION 203mm 7 3/16" 11 5/16" 182mm ENTREÉ DE GAZ 288mm 18 1/2" 470mm GX70 ILLUSTRÉ 1 15/16" 35" 50mm 890mm W415-1519 / C / 11.06.15...
  • Page 70 INSTRUCTIONS GÉNÉRALES AVERTISSEMENT ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE. PRÉVOYEZ UN ACCÈS SUFFISANT POUR ENTRETENIR ET OPÉRER L’APPAREIL. ASSUREZ-VOUS D'UNE QUANTITÉ SUFFISANTE D’AIR DE VENTILATION. N’OBSTRUEZ JAMAIS L’OUVERTURE DE L’APPAREIL.
  • Page 71 INFORMATIONS GÉNÉRALES POUR VOTRE SATISFACTION, CET APPAREIL A ÉTÉ MIS À L'ESSAI POUR CONFIRMER SON FONCTIONNEMENT ET SA QUALITÉ! RENDEMENTS ET EFFICACITÉS GX70 Altitude (PI) 0-4,500 0-4500 Débit max. (BTU/H) 35,000 32,000 Pression minimale 4.5" (11mb) de co-lonne d'eau 11" (27mb) w.c. d'alimentation en gaz Max.
  • Page 72 VENT BOTTOM / EVENT INFERIEUR EVENT INFERIEUR INFERIE 2" L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A NAPOLEON. MANTEL / MANTEAU 10 1/2 ” REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. IL EST * MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 2". SEE INSTRUCTION...
  • Page 73 3.0 ÉVACUATION AVERTISSEMENT RISQUE D’INCENDIE. CONSERVEZ LES DÉGAGEMENTS NÉCESSAIRES AU CONDUIT D’ÉVENT ET À L’APPAREIL. SI LE SYSTÈME D’ÉVENT EST FOURNI AVEC DES ESPACEURS, LES COURSES HORIZONTALES ET VERTICALES DU SYSTÈME DOIVENT ÊTRE SUPPORTÉES À TOUS LES 3 PI (0,9m). UTILISEZ DES SUPPORTS OU DES ATTACHES INCOMBUSTIBLES ÉQUIVALENTS AFIN DE MAINTENIR LE DÉGAGEMENT AUX MATÉRIAUX COMBUSTIBLES.
  • Page 74 LONGUEURS DES CONDUITS D’ÉVACUATION ET COMPOSANTS Utilisez uniquement des composants d’évacuation Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent ou Metal-Fab. Les minimums et maximums des longueurs d’évent, pour les installations verticales et horizontales, et les emplacements des terminaisons pour les deux systèmes sont précisés dans ce manuel et doivent être respectés.
  • Page 75 INSTALLATIONS TYPIQUES D'ÉVENTS 16" (406MM) MINIMUM 440 PI (12M) AVERTISSMENT! MAXIMUM 3 PI (1M) LE PREMIER DEUX PIEDS DE CONDUIT EXTÉRIEUR DE MINIMUM 8” DE DIAMÈTRE À PARTIR DE L’APPA-REIL DOIT ÊTRE ENVELOPPÉ DANS UN MANCHON ISOLANT DE 1” (25MM) D’ÉPAISSEUR (FOURNI).
  • Page 76 18" (610MM) MAXIMUM 15 1/8" (384MM) AVERTISSMENT! MINIMUM LE PREMIER DEUX PIEDS DE CONDUIT EXTÉRIEUR DE 48 1/4" (1226MM) 8”( 203MM) DE DIAMÈTRE À MINIMUM PLUS PARTIR 34 5/8" LA PENTE* DE L’APPA-REIL DOIT ÊTRE (879MM) ENVELOPPÉ DANS UN MANCHON ISOLANT DE 1”...
  • Page 77 EMPLACEMENTS ET DÉGAGEMENTS MINIMAUX DE LA TERMINAISON ††* APPLICATIONS POUR BALCON COUVERT INSTALLATION = 3 pieds = 2 x RÉELLE (4,6m) (0,9m) CANADA É.-U. 12” 12” Dégagement au-dessus du sol, d’une véranda, d’une terrasse en bois ou d’un balcon. (304,8mm) (304,8mm) 12”...
  • Page 78 CHARTE D'APPLICATION DES ÉVACUATIONS ÉVACUATION SUR LE DESSUS Terminaison horizontale Terminaison verticale La course verticale La course verticale La course verticale est La course verticale est est plus petite que la est plus petite que la plus grande ou égale à plus grande ou égale à...
  • Page 79 TERMINAISON HORIZONTALE ) < (V Configuration d'évacuation simple (un coude de 90° Consultez le graphique pour déterminer la course verticale seulement). nécessaire V par rapport à la course horizontale requise H 40 (12,2) 39 (11,9) 30 (9,1) COURSE VERTICALE REQUISE EN 20 (6,1) PIEDS (MÈTRES) V...
  • Page 80 ) > (V Configuration d'évacuation simple Consultez le graphique pour déterminer la course verticale (un coude de 90° seulement). nécessaire V par rapport à la course horizontale requise H 150 (3810) 147 (3733.8) COURSE VERTICALE REQUISE EN 100 (2540) POUCES (MILLIMÈTRES) V 57 (1447.8) 50 (1270)
  • Page 81 ÉVACUATION SUR LE DESSUS TERMINAISON VERTICALE ) < (V Configuration d'évacuation simple. Consultez le graphique pour déterminer la course verticale nécessaire V par rapport à la course horizontale requise H 40 (12,2) 30 (9,1) COURSE VERTICALE REQUISE EN 20 (6,1) PIEDS (MÈTRES)V 10 (3,1)
  • Page 82 ) > (V Configuration d'évacuation simple. Consultez le graphique pour déterminer la course verticale nécessaire V par rapport à la course horizontale requise H 20 (6,1) 19 (5,8) COURSE VERTICALE REQUISE EN 10 (3,1) PIEDS (MÈTRES) V 3 (0,9) (1,5) (3,1) (4,6) (6,1)
  • Page 83 4.0 INSTALLATION AVERTISSEMENT AVANT D’EFFECTUER LES BRANCHEMENTS POUR L’ALIMENTATION EN GAZ ET ÉLECTRIQUE, ASSUREZ-VOUS DE RETIRER TOUTE COMPOSANTE NON FIXÉE À L’INTÉRIEUR DE LA CHAMBRE DE COMBUSTION. SI VOTRE APPAREIL COMPREND UN SYSTÈME DE TÉLÉCOMMANDE, ASSUREZ-VOUS QUE LE RÉCEPTEUR EST À LA POSITION « OFF » AVANT D’EFFECTUER LES BRANCHEMENTS POUR L’ALIMENTATION EN GAZ ET ÉLECTRIQUE.
  • Page 84 4.1.1 INSTALLATION HORIZONTALE AVERTISSEMENT L’ESPACEUR COUPE-FEU DOIT ÊTRE INSTALLÉ AVEC L’ÉCRAN PROTECTEUR ORIENTÉ VERS LE HAUT. LA TERMINAISON NE DOIT PAS ÊTRE ENCHÂSSÉE DANS LE MUR OU LE REVÊTEMENT EXTÉRIEUR PLUS QUE L’ÉPAISSEUR DE LA BRIDE DE LA PLAQUE DE MONTAGE. Cette confi...
  • Page 85 UTILISATION DE COMPOSANTS FLEXIBLES D’ÉVACUATION AVERTISSEMENT NE LAISSEZ PAS LA GAINE FLEXIBLE SE TASSER CONTRE LES COURSES HORIZONTALES OU VERTICALES ET LES COUDES. GARDEZ-LA TENDUE. DES ESPACEURS SONT FIXÉS À LA GAINE FLEXIBLE À INTERVALLES PRÉDÉTERMINÉS AFIN DE GARDER UN ESPACE VIDE AVEC LE CONDUIT EXTÉRIEUR. POUR QUE LE FONCTIONNEMENT SOIT SÉCURITAIRE, UN ESPACE VIDE EST REQUIS.
  • Page 86 4.2.2 INSTALLATION DE LA TERMINAISON VERTICALE AVERTISSEMENT CONSERVEZ UN ESPACE MINIMAL DE 2" (50,8mm) ENTRE LA BASE DE LA PRISE D’AIR ET LE COLLET DE SOLIN. Fixez le support de toit au toit à l’aide des vis fournies. Le support de toit est optionnel.
  • Page 87 4.2.3 RACCORDEMENT DES ÉVENTS À L'APPAREIL Raccordez la collet d’évacuation à l’appareil. Fixez-la à l’aide de trois vis. Scellez le joint et les têtes de vis avec AUTOPER- le scellant à haute température Mill-Pac W573-0007 (non CEUSES fourni). #8 X 1/2” CHEVAUCHEMENT DE 2”...
  • Page 88 4.3.2 INSTALLATION DE LA TERMINAISON VERTICALE Mettez l’appareil en place. CONDUIT Fixez le support de toit au toit à l’aide des vis fournies. Le support de toit INTÉRIEUR est optionnel. Dans ce cas, l’évent doit être supporté adéquatement, soit en utilisant une méthode alternative se conformant aux normes des autorités compétentes, soit en utilisant le support de toit optionnel.
  • Page 89 INSTALLATION DANS UNE MAISON MOBILE Cet appareil est certifi é pour être installé comme équipement d’origine (OEM) dans une maison préfabriquée ou une maison mobile. Son installation doit être effectuée en respectant les directives du fabricant et le Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, aux États-Unis, ou les normes actuelles pour les maisons mobiles, CAN/CSA Z240 SÉRIE MH, au Canada.
  • Page 90 BRANCHEMENT DU GAZ AVERTISSEMENT RISQUE D'INCENDIE, D'EXPLOSION OU D'ASPHYXIE. ASSUREZ-VOUS QU'IL N'Y AIT AUCUNE SOURCE D'ALLUMAGE COMME DES ÉTINCELLES OU UNE FLAMME NUE. SOUTENEZ LE CONTRÔLE DU GAZ LORSQUE VOUS ATTACHEZ LE TUYAU POUR ÉVITER DE PLIER LA CON- DUITE DE GAZ. ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE.
  • Page 91 5.0 OSSATURE AVERTISSEMENT RISQUE D’INCENDIE! AFIN D’ÉVITER LA POSSIBILITÉ QUE DE L’ISOLATION OU UN COUPE-VAPEUR ENTRENT EN CON- TACT AVEC L’EXTÉRIEUR DU CAISSON, IL EST CONSEILLÉ D’INSTALLER L’APPAREIL CONTRE DES MURS FINIS (C.-À-D. PANNEAU DE GYPSE) COMME TOUT AUTRE MUR DE LA MAISON. CECI ASSURERA QUE LE DÉGAGEMENT AUX MATÉRIAUX COMBUSTIBLES EST MAINTENU.
  • Page 92 DIMENSIONS MINIMALES DE L’OSSATURE 39 5/8" [1006mm] 34 5/8" [879mm] 1 15/16"[49mm] 18 9/16" 471mm *Basée sur la 1/2" matériau de fi nition W415-1519 / C / 11.06.15...
  • Page 93 ll est préférable de construire l'ossature après que l'appareil est en place et que le système d'évacuation est installé. Construisez conformément aux exigences des codes du bâtiment locaux. Il n'est pas nécessaire d'installer une base de protection avec ce type d'appareil. Lorsque vous mettez l'appareil en place, surélevez-le de façon à...
  • Page 94 DÉGAGEMENTS MINIMAUX DE L'ENCEINTE COMBUSTIBLE INCOMBUSTIBLE BRIQUE 3" 0” (0MM) SI LES 76mm MATÉRIAUX SONT INCOMBUSTIBLES, COMME DE LA BRIQUE ET DE LA PIERRE. MANCHES INCOMBUSTIBLE MYLAR MATÉRIEL 2" 51mm 6 3/4" [883mm] L’ A SSEMBLAGE DE L’ESPACEUR 78" COUPE-FEU 1981mm PLAFOND OSSATURE EN ACIER...
  • Page 95 5.2.1 DÉGAGEMENTS MINIMAUX DE L'ENCEINTE EN ALCÔVE 3" 0” (0MM) SI LES 76mm MATÉRIAUX SONT INCOMBUSTIBLES, MANCHES COMME DE LA COMBUSTIBLE MYLAR BRIQUE ET DE LA PIERRE. 4 1/2" 114mm INCOMBUSTIBLE MATÉRIEL 2" 51mm 7.5" 59 1/2" 191mm ’ A SSEMBLAGE 1511mm DE L’ESPACEUR PLAFOND...
  • Page 96 INSTALLATION ENCADRÉE WARNING AVERTISSEMENT L’INSTALLATION D’UNE TÉLÉVISION OU D’AUTRES APPAREILS ÉLECTRONIQUES DESSUS DE L’APPAREIL PEUT PROVOQUER LA DÉCOLORATION, FUSION OU DOMMAGE L’APPAREIL ÉLECTRONIQUE. UTILISER LES DÉGAGEMENTS À TITRE INFICATIF ET SE RÉFÉRER AUX INSTRUCTIONS DE VOTRE FABRICANT POUR PLUS D’INFORMATIONS. AVERTISSEMENT: Les matériaux de fi...
  • Page 97 MATÉRIAU DE FINITION INCOMBUSTIBLE AVERTISSEMENT: Les matériaux de finition incombustibles ne doivent pas dépasser de plus 4” (101,6mm) la façade de la porte (sur toutes côtés). Si des projections plus grandes sont requises, augmentez les dégagements des côtés et du dessus de 2"...
  • Page 98 DÉGAGEMENTS MINIMAUX DE LA TABLETTE AVERTISSEMENT RISQUE D’INCENDIE. CONSERVEZ TOUS LES DÉGAGEMENTS AUX MATÉRIAUX COMBUSTIBLES SPÉCIFIÉS. NE PAS RESPECTER CES INSTRUCTIONS PEUT CAUSER UN INCENDIE OU UNE SURCHAUFFE. ASSUREZ-VOUS QUE TOUS LES DÉGAGEMENTS (ARRIÈRE, CÔTÉS, DESSUS, ÉVENTS, TABLETTE, FAÇADE, ETC.) SONT RESPECTÉS À LA LETTRE. LORSQUE VOUS UTILISEZ DE LA PEINTURE OU DU VERNIS COMME FINITION POUR VOTRE TABLETTE, ASSUREZ-VOUS QU’ILS SOIENT RÉSISTANTS À...
  • Page 99 6.0 FINITIONS AVERTISSEMENT RISQUE D’INCENDIE! N’OBSTRUEZ JAMAIS L’OUVERTURE SUR LE DEVANT DE L’APPAREIL. LA FAÇADE DE L’APPAREIL DOIT ÊTRE FAITE DE MATÉRIAUX INCOMBUSTIBLES COMME DE LA BRIQUE, DU MARBRE, DU GRANITE, ETC., À CONDITION QUE CES MATÉRIAUX NE SE TROUVENT PAS EN DEÇÀ...
  • Page 100 OUVERTURE ET FERMETURE DE LA PORTE ET L'ÉCRAN DE PROTECTION AVERTISSEMENT LA VITRE PEUT ÊTRE CHAUDE, NE TOUCHEZ PAS LA VITRE JUSQU’À CE QU’ELLE AIT REFROIDI. LES LOQUETS DE PORTE FONT PARTIE D'UN DISPOSITIF DE SÉCURITÉ ET DOIVENT ÊTRE ADÉQUATEMENT VERROUILLÉS.
  • Page 101 DISPOSITION DES BÛCHES AVERTISSEMENT OMETTRE DE POSITIONNER LES BÛCHES CONFORMÉMENT AUX SCHÉMAS OU OMETTRE D’UTILISER UNIQUEMENT DES BÛCHES SPÉCIFIQUEMENT APPROUVÉES POUR CET APPAREIL PEUT CAUSER DES DOMMAGES MATÉRIELS OU DES BLESSURES CORPORELLES. LES BÛCHES DOIVENT ÊTRE PLACÉES CORRECTEMENT À L’INTÉRIEUR DE L’APPAREIL. NE CHANGEZ PAS LA POSITION DES BÛCHES CAR L’APPAREIL RISQUE DE NE PAS FONCTIONNER ADÉQUATEMENT ET UN RETARD D’ALLUMAGE RISQUE DE SE PRODUIRE.
  • Page 102 Placez l’extrémité de la bûche no 5 sur Placez la bûche no 6 le long de l’extrémité l’extrémité gauche de la bûche no 1 et sur arrière de la grille entourant le 3e poteau de la tige de la bûche no 2. la grille.
  • Page 103 SCHÉMA DE CÂBLAGE (ELECTRONIQUE) AVERTISSEMENT NE RACCORDEZ PAS L’INTERRUPTEUR MURAL OU LA SOUPAPE DE GAZ À L’ALIMENTATION ÉLECTRIQUE (110 VOLTS). FUSIBLE LUMIÈRE SOUFFLERIE SOUFFLERIE VEILLE COMBUSTION INTERFACE INTERFACE UTILISATEUR DIAGNOSTIC NOTE: Pour votre protection contre les risques de chocs électriques, cet appareil est muni d’une fi...
  • Page 104 7.0 FONCTIONNEMENT GX70NT & GX70PT (MILLIVOLT) AVERTISSEMENT SI CES INSTRUCTIONS NE SONT PAS SUIVIES À LA LETTRE, UN INCENDIE OU UNE EXPLOSION POUR- RAIENT S’ENSUIVRE, CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU DES PERTES DE VIE. ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE.
  • Page 105 GX70NTE & GX70PTE (ELECTRONIQUE) AVERTISSEMENT SI CES INSTRUCTIONS NE SONT PAS SUIVIES À LA LETTRE, UN FEU OU UNE EXPLOSION POURRAIENT S’ENSUIVRE, CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES COR- PORELLES OU DES PERTES DE VIE. ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE.
  • Page 106 DESSIN GÉNÉRAL DE LA TÉLÉCOMMANDE (ÉLECTRONIQUE SEULEMENT) Verrou L’alarme de faible piles Transmission Temperature du salle Mode CPI Flame Marche Lumière DEL Soufflerie (PAS DISPONIBLE AVEC CE MODÈLE) PREMIÈRE INITIALISATION DE LA TÉLÉCOMMANDE/BLOC-PILES Installez 4 piles AA dans le bloc-piles du Profl ame 2, notez la polarité des piles puis insérez-les comme indiqué...
  • Page 107 AFFICHEUR DE TEMPÉRATURE Avec le système en position «OFF», appuyez simultanément sur les touches «TEMPÉRATURE» °F °C et « MODE » pour passer de l’affi chage de la température en Fahrenheit à Celsius. Vérifi ez l’affi cheur ACL de la télécommande pour vous assurer que le C ou le F est visible à...
  • Page 108 VEILLEUSE GRADATEUR ACCÈS AUX CONTRÔLES La fonction auxiliaire contrôle le veilleuse avec le con- °F °F trôle de dimmable. Utiliser le clé de mode pour vous diriger à l’icône du veilleuse. L’intensité de la production peut être ajustée par 6 niveaux. Utiliser les controls EN HAUT/ EN BAS pour ajuster le niveau de puissance.
  • Page 109 7.12 INSTALLATION DU BOÎTIER À PILES/PILES DE SECOURS (ÉLECTRONIQUE SEULEMENT) Le boîtier à piles se trouve dans le compartiment de la soupape, auquel il est possible d’accéder pour confi gurer le récepteur. Installez 4 piles AA (non fourni) dans le bloc-piles du boîtier fourni, notez la polarité...
  • Page 110 8.0 RÉGLAGES RÉGLAGE DE LA VEILLEUSE Ajustez la vis de la veilleuse pour obtenir une fl amme de taille normale. Tournez vers la droite pour réduire l’apport de gaz. VÉRIFIER LA PRESSION : Pour vérifi er la pression d’arrivée, tournez la vis (A) vers la gauche deux à...
  • Page 111 CARACTÉRISTIQUES DE LA FLAMME Il est important d’effectuer périodiquement une inspection visuelle de la fl amme de la veilleuse et du brûleur. Comparez-les à ces illustrations. Si des fl ammes paraissent anormales, contactez un technicien de service. ÉLECTRODE VEILLEUSE 3/8” - 1/2” (9,5mm - 12,7mm) LA SONDE DE FLAMME...
  • Page 112 ENTRETIEN ANNUEL AVERTISSEMENT LE CAISSON DEVIENT TRÈS CHAUD LORS DU FONCTIONNEMENT. LAISSEZ L’APPAREIL SE REFROIDIR COMPLÈTEMENT OU PORTEZ DES GANTS ANTICHALEUR AVANT D’EFFECTUER L’ENTRETIEN. NE JAMAIS ASPIRER DES BRAISES QUI SONT CHAUDES. NE PEINTUREZ PAS L’ASSEMBLAGE DE LA VEILLEUSE. • Cet appareil nécessite un entretien qui devra être effectué...
  • Page 113 10.0 RECHANGES AVERTISSEMENT OMETTRE DE POSITIONNER LES PIÈCES CONFORMÉMENT À CE MANUEL OU D’UTILISER UNIQUEMENT DES PIÈCES SPÉCIFIQUEMENT APPROUVÉES POUR CET APPAREIL PEUT CAUSER DES DOMMAGES MATÉRIELS OU DES BLESSURES CORPORELLES. ** CECI EST UN THERMOCOUPLE À ACTION RAPIDE QUI CONSTITUE UN COMPOSANT ESSENTIEL DE SÉCURITÉ.
  • Page 114 10.2 REMPLACEMENT DE LA VITRE/PORTE AVERTISSEMENT N’UTILISEZ PAS DE MATÉRIAUX DE SUBSTITUTION. LA VITRE PEUT ÊTRE CHAUDE, NE TOUCHEZ PAS LA VITRE JUSQU’À CE QU’ELLE AIT REFROIDI. USEZ DE PRUDENCE LORSQUE VOUS ENLEVEZ ET JETEZ DES DÉBRIS DE VERRE OU DES COMPOSANTS ENDOMMAGÉS. ASSUREZ-VOUS D’ASPIRER TOUS LES DÉBRIS DE VERRE À...
  • Page 115 10.3 INSTALLATION DE LA SOUFFLERIE AVERTISSEMENT RISQUE D’INCENDIE ET DE CHOC ÉLECTRIQUE. COUPEZ L’ALIMENTATION EN GAZ ET L’ALIMENTATION ÉLECTRIQUE AVANT DE PROCÉDER À L’ENTRETIEN DE L’APPAREIL. N’UTILISEZ QUE LES ACCESSOIRES OPTIONNELS ET LES PIÈCES DE RECHANGE APPROUVÉS PAR WOLF STEEL POUR CET APPAREIL. L’UTILISATION D’ACCESSOIRES NON LISTÉS (SOUFFLERIE, PORTES, PERSI- ENNES, MOULURES, COMPOSANTS DE GAZ, COMPOSANTS D’ÉVACUATION, ETC.) POURRAIT ÊTRE NON SÉCURITAIRE ET ANNULERA LA GARANTIE ET LA CERTIFICATION.
  • Page 116 W415-1519 / C / 11.06.15...
  • Page 117 W415-1519 / C / 11.06.15...
  • Page 118 W415-1519 / C / 11.06.15...
  • Page 119 W415-1519 / C / 11.06.15...
  • Page 120 15.0 GUIDE DE DÉPANNAGE (ÉLÉCTRONIQUE) MAINTENANCE MAINTENANCE AVERTISSEMENT MAINTENANCE ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE. COUPEZ L’ALIMENTATION EN GAZ ET L’ALIMENTATION ÉLECTRIQUE AVANT DE PROCÉDER À L’ENTRETIEN DE L’APPAREIL.
  • Page 121 SYMPTÔME PROBLÈME SOLUTIONS Du carbone se Le volet d’air est bloqué. Assurez-vous que l’ouverture du volet d’air n’est pas bloquée par dépose sur la des fi bres ou autres obstructions. vitre, les bûches, Les fl ammes effl eurent la vitre, - Vérifi...
  • Page 122 SYMPTÔME PROBLÈME SOLUTIONS Une pellicule Le soufre du combustible Nettoyez la vitre avec un nettoyeur recommandé. NE blanche ou grise se dépose sur la vitre, les PAS NETTOYER LORSQU’ELLE EST CHAUDE. se forme. bûches ou les parois de la Si vous ne nettoyez pas les dépôts régulièrement, la chambre de combustion.
  • Page 123 16.0 GUIDE DE DÉPANNAGE (MILLIVOLT) MAINTENANCE MAINTENANCE AVERTISSEMENT MAINTENANCE ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE. COUPEZ L’ALIMENTATION EN GAZ ET L’ALIMENTATION ÉLECTRIQUE AVANT DE PROCÉDER À L’ENTRETIEN DE L’APPAREIL.
  • Page 124 SYMPTÔME PROBLÉME SOLUTIONS La veilleuse ne Aucune étincelle au brûleur de Vérifi ez si la veilleuse peut être allumée avec une allumette. s’allume pas. la veilleuse. Vérifi ez si le fi l est raccordé au bouton-poussoir d’ignition. Vérifi ez si le bouton-poussoir d’ignition doit être resserré. VEILLEUSE Remplacez le fi...
  • Page 125 SYMPTÔME PROBLÈME SOLUTIONS Une pellicule Le souffre du combustible Nettoyez la vitre avec un nettoyeur recommandé. NE PAS NETTOYER LORSQU’ELLE EST CHAUDE. blanche ou grise se se dépose sur la vitre, les Si vous ne nettoyez pas les dépôts régulièrement, la vitre risque de forme.
  • Page 126 17.0 GARANTIE Les produits Napoléon® sont fabriqués conformément aux normes strictes du Certifi cat d’Assurance de la Qualité mondialement reconnu ISO 9001 : 2008. Les produits Napoléon® sont conçus avec des composants et des matériaux de qualité supérieure, assemblés par des artisans qualifi...
  • Page 127 18.0 HISTORIQUE D'ENTRETIEN W415-1519 / C / 11.06.15...
  • Page 128 Poêles à bois • Produits HVAC • Foyers électriques • Foyers extérieurs • Grils à gaz de qualité 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8...

Ce manuel est également adapté pour:

Gx70nteGx70ptGx70pte