6.5.1 GLOWING EMBERS

DO NOT BLOCK THE BURNER PORTS. BLOCKED PORTS CAN CAUSE AN INCORRECT FLAME
Tear the embers into pieces and place along the front row of ports covering all of the burner area in front of
the small logs. Care should be taken to shred the embers into thin, small irregular pieces as only the exposed
edges of the fibre hairs will glow. The ember material will only glow when exposed to direct flame;
however, care should be taken to not block the burner ports.
Blocked burner ports can cause an incorrect flame pattern, carbon deposits and delayed ignition. PHAZER
logs glow when exposed to direct flame. Use only certified "glowing embers" and PHAZER
from your local authorized dealer / distributor.

6.5.2 CHARCOAL EMBERS

DO NOT BLOCK THE BURNER PORTS. BLOCKED PORTS CAN CAUSE AN INCORRECT FLAME
Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner.
Fine dust found in the bottom of the bag should not be used.
NOTE: Charcoal embers are not to be placed on the burner.

7.0 WIRING DIAGRAM

7.1

RECEPTACLE WIRING DIAGRAM

L1 (Black)
Cable connector
7.2

ELECTRONIC WIRING DIAGRAM

DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. CALL A QUALIFIED
SERVICE TECHNICIAN IMMEDIATELY TO HAVE THE APPLIANCE INSPECTED FOR DAMAGE TO THE
RISK OF ELECTRICAL SHOCK OR EXPLOSION. DO NOT WIRE 110V TO THE VALVE OR TO THE
APPLIANCE WALL SWITCH. INCORRECT WIRING WILL DAMAGE CONTROLS.
ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE
WITH LOCAL CODES. IN THE ABSENCE OF LOCAL CODES, USE THE CURRENT CSA22.1 CANADIAN
ELECTRIC CODE IN CANADA OR THE CURRENT NATIONAL ELECTRIC CODE ANSI/NFPA NO. 70 IN
ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT,
!
PATTERN, CARBON DEPOSITS AND DELAYED IGNITION.
!
PATTERN, CARBON DEPOSITS AND DELAYED IGNITION.
Electrical box
cover
Screw
Ground
L2
(Green)
(White)
!
ELECTRICAL CIRCUIT.
THE UNITED STATES.
WITH THE GLASS DOOR OPENED OR REMOVED.
WARNING
WARNING
(Black)
(White)
Wire nuts
Ground
(Green)
WARNING
logs available
TM
32.1
3 prong
receptacle
Electrical
box
69.2_2
W415-1519 / H / 03.22.17
35
EN
TM