82
5.2.1 DÉGAGEMENTS MINIMAUX DE L'ENCEINTE EN ALCÔVE
FR
78"
[198cm]
HAUTEUR DU
COMPARTIMENT
59 1/2"
[151,1cm]
PLAFOND
* Voir la section « ÉVACUATION »
IMPORTANT: L'ASSEMBLAGE DE L'ESPACEUR COUPE-FEU FOURNI DOIT ÊTRE UTILISÉ LORSQUE
LES CONDUITS D'ÉVENTS PASSENT À TRAVERS UN MUR, UN PLANCHER OU UN PLAFOND
COMBUSTIBLE.
REMARQUE: LE VOLUME MINIMAL DE L'ENCEINTE DOIT ÊTRE AUGMENTÉ D'AU MOINS LA VALEUR DU
VOLUME DE LA ZONE ENCASTRÉE. CET AJUSTEMENT PEUT ÊTRE RÉALISÉ EN AUGMENTANT UNE OU
TOUTES LES DIMENSIONS DE L'ENCEINTE.
W415-1519 / H / 03.22.17
COMBUSTIBLE
MATÉRIAU
MAX.
INCOMBUSTIBLE
4 1/2"
[114mm]
7 1/2"
[191mm]
OSSATURE
EN ACIER
42 3/8"
[107,6cm]
34 7/8"
[88,6cm]
MANCHON
COMBUSTIBLE
INCOMBUSTIBLE
MANCHON
MYLAR
1" [25mm]
COMBUSTIBLE
INCOMBUSTIBLE
BRIQUE
3"
0" (0MM) SI LES
[76mm]
MATÉRIAUX SONT
INCOMBUSTIBLES,
COMME DE LA
BRIQUE ET DE
LA PIERRE.
2"
[51mm]
ASSEMBLAGE
DE L'ESPACEUR
COUPE-FEU
49 3/4"
[126,4cm]
MINIMUM
PLUS
LA PENTE *
BRIQUE
0" (0MM) SI LES
3"
MATÉRIAUX SONT
[76mm]
INCOMBUSTIBLES,
COMME DE LA
BRIQUE ET DE