6.
Measurement bay requi-
rements
6.1

Ambient conditions

6.1.1

Evenness of measurement bay

The unevenness of the SCT 415 S52 measurement bay
must not exceed 1 mm. The unevenness of the vehicle con-
tact surface is 10 mm.
6.1.2

Test bay conditions

i
Operate the measurement as specified by the manufacturer.
R
Avoid direct sunlight at the measurement bay.
R
Ensure adequate lighting.
i
The background behind the measurement boards must
not be too bright.
7.

Transportation

7.1

SCT 415 S52

1. Move cross beam to the lowest position.
2. Place the movable plate at the middle position.
3. Lock the eccentric clamp.
4. Set positioning feet to the uppermost position.
5. Secure the ruler in the raised position.
6. Move and guide only by means of the column.
7. Transport the SCT 415 S52.
!
When moving, make sure that the cross beam does not
strike anything.
!
The SCT 415 S52 may be moved only by means of
the column, not the cross beam.
1 Eccentric clamp
2 Movable plate
3 Middle position
Robert Bosch GmbH
Measurement bay requirements | SCT 415 S52 | 39
7.2
(may be included in delivery, depending on the version ordered.)
!
!
7.3
1 Grip opening
3

P-Assist

Move or carry only by means of the strut profile.
Do not carry by the adjuster or laser mount.
An uneven floor poses a risk of tipping.

Distance reference stand

1
Move and carry only by means of the grip opening.
en
|
1 690 386 051