TABLE 1
Keys
Paired command
T1
Step-by-Step (SbS)
T2
Partial open
T3
Open only
T4
Close only
T5
230 V light output: On - Off
Memorisation procedure
01. On the control unit (Fig. 21) press and hold button P4 for 3 seconds; when led L4 switches on, release the button.
02. Within 10 seconds from releasing it, press and hold for 3 seconds any button of the transmitter to be memorised.
If the memorisation procedure is successful, led L4 (on the control unit) will flash 3 times.
03. To memorise other transmitters, repeat step 02 within the next 10 seconds otherwise the memorisation phase will terminate automatically.
5.6 - BASIC ADJUSTMENTS
5.6.1 - Choosing the gate manoeuvre speed
The opening and closing manoeuvre speed of the gate can be either "slow" or "fast" (the type of selection chosen is visualised by the switching on
or off of led L2 on the control unit – Fig. 22):
Led L2 off = the "slow" manoeuvre speed was selected.
Led L2 on = the "fast" manoeuvre speed was selected.
Procedure for selecting the desired speed
01. Press and release button P2 to invert the operating mode from slow to fast and vice-versa (Fig. 22).
5.6.2 - Choosing the gate manoeuvre operating cycle
The "opening and closing" manoeuvre cycle of the gate can be either "semi-automatic" or "automatic" (the type of selection chosen is visualised by
the switching on or off of led L3 on the control unit – Fig. 23):
Led L3 off = the "semi-automatic" manoeuvre cycle was selected (with the first command the gate opens and stays open until the next command
that causes it to close).
Led L3 lit = the "automatic" manoeuvre cycle was selected (with a single command the gate opens and re-closes automatically after a set time – to
adjust the pause time see Par. 9.1.1).
Procedure for selecting the desired cycle
01. Press and release button P3 to invert the operating mode from semi-automatic to automatic and vice-versa (Fig. 23).
22
6
TESTING AND COMMISSIONING
CAUTION! – The system must be tested by skilled and qualified personnel, who is responsible for defining the tests adopted in rela-
tion to the risks present, and for ensuring observance of all legal provisions, standards and regulations, with particular reference to all
requirements of the EN 13241-1and EN 12453 standards which defines the test methods for testing gate automations.
6.1 - TESTING
01. Ensure that all the instructions and warnings indicated in Chapter 1 have been strictly observed.
02. Using the transmitter, test the gate's opening and closing movements and ensure that the leaf movement corresponds to specifications. A number
of tests should be performed to ensure that the gate moves smoothly and that there are no assembly defects, incorrect settings, or any points of
friction.
03. Check the operation of all the system's safety devices one-by-one (photocells, sensitive edges, etc.) In particular, whenever a device is activated
the ECSBus led (on the control unit) must emit a longer flash to confirm that the control unit has recognised the event.
04. To check the photocells and make sure that there is no interference with other devices, pass a cylinder with 5 cm diameter and 30 cm length on
the optical axis, first near the TX then near the RX and, lastly, at the mid-point between the two, and verify that in all these cases the device is
triggered, switching from the active status to the alarm status and vice-versa; lastly, make sure that it causes the intended action in the control unit;
for example: reversal of the movement during the closing manoeuvre.
05. Measure the impact force as specified in the EN 12453 standards. If the "motor force" control is used as an auxiliary function to reduce the impact
force, test and identify the setting that obtains the best results.
LED
T1
T3
Flash
Flash
Fuse 1.6A T
Fuse 1.6A T
ECSbus
ECSbus
Stop
Stop
Sb
Aerial
Aerial
A
al
L4
L4
L3
L3
L2
L2
L1
L1
L4
L3
L2
L1
SbS
SbS
SbS
P4
P3
P2
P1
P4
4
P3
P3
P2
P2
P1
P1
21
T5
T2
T4
23
semi-automatic
automatic
Fuse 1.6A T
Fuse 1.6A T
Aerial
L4
L4
L3
L3
L4
L3
L
L 3
3
L2
L2
P4
P
P3
P 3
3
3
P2
P2
P4
P4
P3
P3
Flash
Flash
Fuse 1.6A T
Fuse 1.6A T
OGI
OGI
ECSbus
ECSbus
Stop
Stop
SbS
SbS
Aerial
L4
L4
L3
L3
L2
L2
L4
L3
L2
L 1
L1
L
S
S b
SbS
bS
P4
P3
P2
P 1
P
P1
1
P4
P4
P3
P3
P2
P2
English – 8
OGI
OGI
ECSbus
ECSbus
Stop
Stop
SbS
SbS
L1
L1
SbS
SbS
P1
P1