Outdoor Reset - Rinnai E50CRN Manuel D'installation

Chaudière gaz à condensation haut rendement
Masquer les pouces Voir aussi pour E50CRN:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Service Mode
SERV
VALUE
DESCRIPTION
1
OFF
boiler in operation with burner function on
2
OFF
fan adjustable and burner off
3
OFF
pump adjustable with burner on
4
OFF
showroom position ON = active and OFF = non active
.
.
.
Error Mode
ERRO
DESCRIPTION
VALUE
Err.L - Err.5
Last saved error until 5 last previous errors
1
error code
2
operation status boiler
3
°F
supply water temperature T1
4
°F
return water temperature T2
5
kW
load (.. x3415 = .. BTU/hr)
6
%
pump capacity
Parameter-, Info-, Service- and Error-chapters
i
NOTICE
*
Most of the data in this table can be requested by the RS100. Most of
the adjustments which are stated in this table are unnecessary when in
combination with the Rinnai RS100 thermostat and will be taken care of
by the RS100 itself and do not have to be adjusted. For further information
regarding to the RS100 thermostat refer to the Rinnai RS100 installation
manual.
230
2.30
212
194
2.30
1.80
176
1.50
1.80
158
1.50
140
1.00
122
1.00
104
86
68
50
heating line adjustments Parameter Step 6 and 7

Outdoor reset

outside temperature in °F
RANGE
OFF - max.
OFF - max.
OFF - max.
ON - OFF
.
Table 12
Heat curve day
Heat curve night
graph 2
57