Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

EX17CT............... (RHFE-434FTA2)
EX22CT............... (RHFE-559FTA2)
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
READ ALL OF THE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR OPERATING
THIS HEATER.
This manual provides information on the installation, operation, and maintenance of the heater. For
proper operation and safety, it is important to follow the instructions and adhere to the safety
precautions.
A licensed professional must install the fan convection heater according to the exact instructions
within this manual.
The consumer must read the entire manual to properly operate the heater and to have regular
maintenance performed.
WARNING
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
 Do not try to light any appliance.
 Do not touch any electrical switch; do not use any phone in your building.
 Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
 If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a licensed professional.
Register your product at www.rinnairegistration.com or call 1-866-RINNAI1 (746-6241)
Installation and Operation Manual
If the information in these instructions is not followed exactly, a fire or explosion
may result causing property damage, personal injury or death.
Direct Vent Wall Furnace

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour Rinnai EX17CT

  • Page 1 Direct Vent Wall Furnace Installation and Operation Manual EX17CT....(RHFE-434FTA2) EX22CT....(RHFE-559FTA2) Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference. READ ALL OF THE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR OPERATING THIS HEATER. This manual provides information on the installation, operation, and maintenance of the heater. For proper operation and safety, it is important to follow the instructions and adhere to the safety precautions.
  • Page 2: Table Des Matières

    We will however, continue to contact you with information relevant to the product(s) you registered and/or your account with us. If you have any questions or feel that the manual is incomplete contact Rinnai at 1-800-621-9419 Important Safety Information Safety Definitions This is the safety alert symbol.
  • Page 3: Safety Behaviors And Practices For The Consumer And Installer

     Do not place containers of liquid on top of the  Do not insert items into the louvers. heater. Water spillage can cause extensive damage to the appliance and may result in electric shock. Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 4: Installation Instructions (For The Licensed Professional)

    State Regulations NOTICE BEFORE INSTALLATION Rinnai direct-vent appliance must be installed by a state qualified or licensed contractor and a properly trained Rinnai Installer. If you are not properly trained, you must not install this unit. IMPORTANT: In the State of Massachusetts (248 CMR 4.00 & 5.00)
  • Page 5: Included Installation And Vent Components

    9 1/2 - 15 3/4 in (240 - 400mm) C Vent Kit FOT-153 15 3/4 - 23 5/8 in (400 - 600 mm) D Vent Kit FOT-154 23 5/8 - 31 1/2 in (600 - 800 mm) Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 6: General Instructions

     Follow the installations instructions and those in carpets containing dyes or vinyl surfaces. Care and Maintenance for adequate combustion  Rinnai suggests that a dedicated electrical circuit and ventilation air. with a 120VAC, 60 Hz, 10 amp power source be used.
  • Page 7: Prepare For Installation

    Materials that may be needed  Heat tape  Pipe insulation  Concrete wall anchors  Optional pipe cover  Optional temperature controller  2 conductor 22 AWG wire for controller  Single gang electrical  Wire nuts Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 8: Flue Terminal Clearances

    [2] Permitted only if veranda, porch, deck, or balcony is fully open on Clearance to opposite wall is 24 inches (60 cm). a minimum of two sides beneath the floor. Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 9: Additional Clearances

    Home Construction and Safety Standard, Title 24 Practices section. CFR, Part 3280 and/or CAN/SCA Z240 MH Series, Mobile Homes. Rinnai recommends 10” (254 mm) clearance from the □ top and on both sides for servicing. Leave the entire manual with the consumer.
  • Page 10: Drilling Flue Hole

     This appliance can only be used with one of the not exhaust into other rooms. five types of Rinnai flue kits. The flue kits and their dimensions are listed in the Specifications section.  The flue manifold is not designed to be positioned ...
  • Page 11 Push the assembly into the terminal tube, ensuring that the seal is in place on the inner tube. Attach the inside connection with 3 screws. The inner connection can still be turned to install the screws. 3 screws Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 12: Extension Kit Installation

     One elbow is shown. One additional elbow may be ance. added.  No elbows are shown. Two additional elbows may  Instructions (1)-(6) must be followed. be added.  Instructions (1)-(6) must be followed. Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 13 Hose joint another air intake hose into the hose joint. Do not cut the intake hose. Cutting NOTICE the intake hose may result in noise. Air intake hoses Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 14 Hose Joint - 1.5 in (38 mm) inner dia. Hose Joint - 2.0 in (50 mm) inner dia. Pipe Stopper A Pipe Stopper B Pipe Clamp 2 sets 3 sets 4 sets Wall Fixture Screw A Screw B Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 15: Connecting The Appliance

    6. Install the wall bracket with two screws. Install the top spacer by clipping the spacer into the wall Top Spacer brackets and attaching it to the heater with 2 screws. Wall bracket Top Spacer Spacer Bracket Wall Bracket Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 16: Gas Connection

    Do not conceal to roughly set pressure and then recheck both the low manual cut-off valve behind back spacer. and high fire pressures. Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 17 4.0 in 2.6 in 2.2 in 2.0 in 1.8 in 3.5 in 3.1 in 2.9 in pressure - (101 mm) (65 mm) (57 mm) (52 mm) (47 mm) (89 mm) (80 mm) (72 mm) W.C. High Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 18 Yellow flames or an orange color is abnormal and maintenance is required. NORMAL Flame Rod Long, clear, blue, stable flames ABNORMAL Flame Rod Yellow flames or orange color Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 19: Final Checklist

    B149.1. If installed in a manufactured home, the installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 and/or CAN/SCA Z240 MH Series, Mobile Homes. □ Leave the entire manual with the consumer. Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 20: Dimensions

    (582 mm) 29.9 in (760 mm) 10.1 in 257 mm 6.8 in 3.3 in 172 mm 85 mm A full size template is provided on the NOTICE cardboard packaging. DO NOT DISCARD until installation is completed. Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 21: Safety Features

    Natural Gas: 80% Propane: 82% AFUE Rating Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice. The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system.
  • Page 22: Direct Vent Furnace Operation Instructions

    EX22CT ....(RHFE-559FTA2) Important Facts about your Direct Vent Furnace Thank you for purchasing a Rinnai Direct Vent Furnace. For proper operation and safety, it is important to follow the instructions and adhere to all safety precautions. Read all of the instructions and the warranty thoroughly before operating this heater. Keep this manual in a safe place.
  • Page 23: Safe Operation

    Keep burner ON/OFF button on the control panel. and control compartment clean. 3.Locate the manual gas valve on the side of the unit. Turn the manual valve clockwise to the full OFF position. Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 24: Getting To Know Your Appliance

    HOLD BOTH SIDES ON THE LEFT AND PULL TOWARD AIR FILTER VENT TERMINAL GAS CONNECTION COMBUSTION AIR/ 1/2” MALE NPT EXHAUST EXHAUST PIPE POWER CORD PLUG 120V AC, 60 Hz COMBUSTION AIR INTAKE HOSE ROOM TEMPERATURE SENSOR/THERMISTOR Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 25: Control Panel

    If activated while the heater is OFF, then all controls will be locked.  If the heater is turned off while the Child Lock is activated, it cannot be turned on again until the lock is deactivated.  Deactivating the lock releases the control buttons. Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 26: Remote Thermostat Mode

    DISPLAY in either mode. Error codes will not show on the remote thermostat even when in remote thermostat mode.) ATTENTION The remote thermostat will NOT control the heaters ability to power on or power down. This must still be done by using the ON/OFF button of the heater. Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 27: Setting The Clock

    The timers can be set while the heater is on or off. To current timer period. operate the timer, the heater must be on. Setting the timers: 1. Press the “Set Times” button twice to set Timer 1. Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 28: Economy (Energy Saving Mode)

    (Default setting at the factory is on.) NOTICE The Set Back feature is intended to prevent the installation location from falling below a specified temperature. It is not intended as an alternate thermostat, but rather a preventative measure against freezing. Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 29: Humidifier And Air Flow Direction

    Use a screw driver or similar object to bend each louver to the desired position. Do not bend repeatedly (no more than 5 times) or else the louver will break. The horizontal louvers (which determines the vertical air flow direction) are fixed and cannot be adjusted. Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 30: Required Care And Maintenance Care And Maintenance

    All maintenance and service is to be performed by a Dirty filters reduce the air flow qualified service technician, preferably one who has and the appliance’s ability to attended Rinnai service training classes on the Direct produce heat. The filters Vent products. should be cleaned frequently during the heating season.
  • Page 31: Before Making A Service Call

    Unit shuts off without apparent reason. Check whether filters are blocked. Dirty filters will cause the heater to overheat. Power Failure. Switch OFF, then ON again when power is restored to re-set controls. Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 32: Diagnostic Codes And Remedies

    You may be able to clear the fault code by turning the furnace off and then on again. If the fault code remains or returns on the next operation, contact Rinnai or your nearest service agent and arrange for a service call.
  • Page 33: Restart Function

    Clear Obstruction Air Filter Blocked Clean Filter Gas Escape Service Call Child Lock Set Cancel Child Lock Gas Off at Meter, Turn Gas On Tank, or Valve ON Timer is set Cancel “ON” Timer No Display Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 34: Cut-Away Diagram

    Cut-Away Diagram Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 35: Wiring Diagram

    THERMAL FUSE CONVECTION FAN MOTOR FUSE SPARKER white ELECTRODE SV1, 2 MAIN SOLENOID VALVE 1, 2 yellow MODULATING SOLENOID COMBUSTION FAN MOTOR gray VALVE orange TRANSFORMER PRESSURE SENSOR brown FLAME ROD W. TH WALL THERMOSTAT Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 36: Ladder Diagram

    Ladder Diagram Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 37: Parts List

    Parts List / Liste de Pièces For replacement parts call Rinnai at 1-800-621-9419. Pour les pièces de rechange, appelez Rinnai au 1-800-621-9419. Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 38 Parts List / Liste de Pièces Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 39 Parts List / Liste de Pièces Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 40 Parts List / Liste de Pièces Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 41 Parts List / Liste de Pièces Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 42 Parts List / Liste de Pièces Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 43 Parts List / Liste de Pièces Pour les pièces de rechange appelez Rinnai au 1-800-621-9419. Part Number (Numéro de la EX22CT- Name Pièce) EX22CT W (white) EX17CT Rear Panel B ensemble de panneau arrière B 209000091 Frame R armature R...
  • Page 44 Air Inlet Packing garniture d’arrivée d’air RHF300F-79 Air Intake Hose D tuyau d’admission d’air RHF1000-130-D Air Inlet Elbow coude d’arrivée d’air RHF1000-132 Connecting Tube tube de connexion 556F-404 Connecting Tube Fixer fixation de tube de connexion 556F-408 Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 45 SV IG Harness toron d’allumeur 205000050 Motor Harness toron de moteur 205000051 High Tension Cord cordon haute tension 205000038 OHS Harness Assy toron de interrupteur de surchauffe 205000052 Convection Motor Harness toron de moteur de convection 205000032 Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 46: Conversion Kits (Optional) / Kits De Conversion (Facultatifs)

    Conversion Kits (Optional) / Kits de conversion (facultatifs) Model For converting to NG For converting to LPG (Modèle) (Pour la conversion NG) (Pour la conversion LPG) EX17CT (RHFE-434FTA2) 204000035 204000039 EX22CT (RHFE-559FTA2) 204000036 204000040 EX22CT-W (RHFE-559FTA2-W) Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 47: Warranty

    What will Rinnai do? Rinnai will repair or replace the covered product or any part or component that is defective in materials or workmanship as set forth. Rinnai will pay reasonable labor charges associated with the repair or replacement of any such part or component.
  • Page 48 Rinnai will replace the product with a comparable product at Rinnai’s discretion. If a component or product returned to Rinnai is found to be free of defects in material or workmanship, or damaged by improper installation or damaged during return shipping, the warranty claim for product, parts and labor may be denied.
  • Page 49 Si vous ne pouvez pas joindre votre fournisseur de gaz, appelez les pompiers. — Installation et interventions de service doivent être effectuées par un professionnel agréé. Enregistrez votre produit sur www.rinnairegistration.com ou téléphonez au 1-866-RINNAI1 (746-6241) Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 50: Définitions De Sécurité

    Marche / Arrêt AVIS: Rinnai partage parfois des informations de contact de clients avec des entreprises qu’il estime pouvoir fournir des produits ou services qui peuvent vous être utiles. En communicant ces informations, vous donnez votre accord pour que nous communiquions vos informations de contact dans ce but. Si vous préférez que vos informations ne soient pas partagées avec ces entreprises, veuillez contacter notre service à...
  • Page 51: Attitudes Et Pratiques De Sécurité Pour Consommateur Et Installateur

    électrique.  N’insérez pas d’objets dans les volets.  Ne pulvérisez pas avec des bombes aérosol près de l’appareil en marche. La plupart de ces bombes contiennent du gaz butane inflammable. Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 52: Instructions D'installation (Pour Professionnel Agréé) Réglementations D'états

    Réglementations d’états AVIS AVANT TOUTE INSTALLATION L’appareil Rinnai à ventilation directe doit être installé par un sous-traitant qualifié ou agréé au niveau de la province, ou un installateur Rinnai correctement formé. Si vous n’avez pas reçu la formation appropriée, vous ne devez pas installer cet appareil.
  • Page 53: Installation Des Composants De La Ventilation Inclus

    9 1/2 - 15 3/4 in (240 - 400mm) C Vent Kit FOT-153 15 3/4 - 23 5/8 in (400 - 600 mm) D Vent Kit FOT-154 23 5/8 - 31 1/2 in (600 - 800 mm) Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 54: Qualifications De L'installateur

     Rinnai recommande d’utiliser un circuit d'alimentation secteur dédié, 120 V/60 Hz, pouvant fournir 10 ampères. Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 55: Préparation Pour L'installation

     couverts par la garantie. Isolant pour tuyaux Bouchons serre-fils  Chevilles pour murs en béton  Cache-tuyau optionnel  Contrôleur de température optionnel  Câble à deux conducteurs 22 AWG pour le contrôleur Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 56: Dégagements De Sortie D'évacuation

    Le dégagement par rapport à un mur opposé est de 24 pouces (60 cm). [2]Autorisé seulement si véranda, porche, plate-forme ou balcon ont une complète ouverture au moins sur deux côtés en-dessous de l’étage. Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 57: Dégagements Additionnels

    à la norme américaine pour Construction de maison Rinnai recommande un dégagement de 254 mm (10") à préfabriqué et sécurité, Titre 24 CFR, Partie partir du dessus et des deux côtés pour les interventions de service.
  • Page 58: Installation Du Collecteur Cheminée

    Le collecteur de cheminée doit sortir sur l’extérieur. N’évacuez L’appareil ne peut être utilisé qu’avec l’un des cinq types de kit pas dans d’autres pièces; de cheminée Rinnai. Ces kits de cheminée et leurs dimensions sont listés en page précédente. ...
  • Page 59: Installation Du Collecteur De Cheminée (Suite)

    Fixez la connexion intérieure avec 3 vis. La connexion intérieure peut toujours être tournée pour installer les vis. 3 vis Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 60: Installation Du Kit D'extension

    (6) Les extensions de ventilation ne doivent pas être dissimulées selon la norme NFPA 54 et doivent rester accessibles pour permettre leur inspection et réparation. Des caches décoratifs sont disponibles chez Rinnai. Ces illustrations montrent 2 façons possibles d’orienter l’extension de la conduite d’évacuation et du tuyau d’admission d’air en partant du collecteur de fumée.
  • Page 61: Installation De La Conduite D'échappement

    Ne coupez pas le tuyau d’amission AVIS d’air. Cela pourrait générer du bruit. Tuyaux d’admission d’air Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 62 Joint de tuyaux - 1.5 po (38 mm) diamètre intérieur Joint de tuyaux - 2.0 po (50 mm) diamètre intérieur Arrêt de tuyau A Arrêt de tuyau B Collier de tuyaux ensemble ensemble ensemble Dispositif mural Écrou Vis A Vis B Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 63: Branchement De L'appareil

    Mettez en place le support mural avec deux vis. Espaceur supérieur Installez l’espaceur supérieur en insérant sa patte dans Support mural le support mural et en le fixant sur le chauffage avec 2 vis. Espaceur supérieur Patte d’espaceur Support mural Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 64: Liste De Contrôle Pour La Ventilation

    être obtenue, retouchez la vis de réglage de la vanne proportionnelle pour fixer en gros la pression, puis revérifiez les pressions à petit feu et à plein feu. Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 65: Réglages De Pression De Gaz (Suite)

    2.2 in 2.0 in 1.8 in 3.5 in 3.1 in 2.9 in differentielle du (101 mm) collecteur - (65 mm) (57 mm) (52 mm) (47 mm) (89 mm) (80 mm) (72 mm) W.C. Haut Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 66: Assemblée Finale

    à la terre. □ Confirmez qu’il n’y a PAS eu d’adaptateur de fiche ni de cordon de rallonge utilisés avec le générateur d’air chaud. Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 67: Liste Des Contrôles Finaux

    à la norme américaine pour Construction de maison préfabriqué et sécurité, Title 24 CFR, Part 3280 et/ou à la norme canadienne CAN/SCA Z240 MH Series (Maison mobile). □ Laissez le manuel complet au consommateur Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 68: Percez Le Trou De Conduite

    Un modèle de taille complète est fourni sur l'emballage en carton. AVIS 10.1 in NE JETEZ pas jusqu'à ce que l'installation est terminée. 257 mm 6.8 in 3.3 in 172 mm 85 mm 22.9 in (582 mm) 29.9 in (760 mm) Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 69: Caractéristiques De Sécurité

    Gaz naturel Gaz naturel Rinnai poursuit constamment la mise à niveau et l’amélioration de ses produits. De ce fait ces spécifications sont su- jettes à changement sans préavis. Le rendement énergétique de cet appareil mesure l’efficacité thermique du produit en utilisation continue, il a été...
  • Page 70: Instructions D'utilisation Générateur D'air Chaud

    AVIS : Rinnai partage parfois des informations de contact de clients avec des entreprises qu’il estime pouvoir fournir des produits ou services qui peuvent vous être utiles. En communicant ces informations, vous donnez votre accord pour que nous communiquions vos informations de contact dans ce but.
  • Page 71: Fonctionnement Sans Risques

    (ON/OFF). de contrôle propres. Reportez-vous aux instructions d’installation et d’utilisation. Repérez le robinet de coupure manuelle de gaz sur le côté du chauffage. Tournez-le dans le sens horaire jusqu’à la fermeture totale (position OFF). Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 72: Connaissance De Votre Appareil

    TENIR LES DEUX CÔTÉS ET TIRER VERS VOUS FILTRE À AIR TERMINAISON DE CONNEXIONS DE GAZ VENTILATION 1/2 mâle NPT COMBUSTION/ ÉVACUATION CONDUITE D’ÉVACUATION FICHE PLUG 120V AC, 60 Hz TUYAU D’ADMISSION D’AIR DE COMBUSTION THERMISTANCE Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 73: Panneau De Commandes

    Si le chauffage a été arrêté pendant que le verrouillage est activé, il ne pourra pas être remis en marche avant que le verrouillage ne soit désactivé.  La désactivation du verrouillage libère les boutons de commande. Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 74: Mode À Thermostat Distant (Accessoire Optionnel)

    à thermostat distant). Le thermostat à distance NE contrôlera PAS la capacité des appareils de chauffage à ATTENTION s'allumer ou à s'éteindre. Cela doit toujours être fait en utilisant le bouton ON / OFF du chauffage. Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 75: Réglage De L'horloge

    Lorsque la fonction de priorité, en appuyant sur le bouton Override retournera l'appareil de chauffage à Réglage des minuteries: l'exploitation de la période de temporisation en cours. 1.Appuyez sur le bouton Set Times deux fois pour régler la minuterie 1. Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 76: Économie (Mode D'économie Énergétique)

    La fonction Set Back permet d'éviter que l'emplacement d'installation ne tombe en dessous d'une température spécifiée. Il n'est pas conçu comme un thermostat de 30 mi- 30 mi- rechange, mais plutôt comme une mesure préventive contre le gel. Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 77: Humidificateur Et Direction De Flux D'air

    Utilisez un tournevis ou un outil similaire pour fléchir chaque latte dans la position voulue. Ne faites pas cette opération fréquemment (pas plus de 5 fois) sinon le registre peuvent casser. Le registre horizontal (qui détermine la direction en hauteur du flux d'air) est fixe et ne peut pas se régler Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 78: Entretien Et Maintenance Entretien Et Maintenance

    Des filtres sales réduisent le flux doivent être menées par un technicien de service qualifié, d’air et la capacité de l’appareil à ayant de préférence suivi les cours de formation de Rinnai produire de la chaleur. Les filtres sur les produits à ventilation directe.
  • Page 79: Avant De Demander Une Intervention

    Regardez si les filtres sont saturés. Cela peut causer une surchauffe de l’appareil. Unit cuts off without apparent reason. Check whether filters are blocked. Dirty filters will cause the heater to overheat. Power Failure. Switch OFF, then ON again when power is restored to re-set controls. Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 80: Codes De Diagnostic

    à la remise en défaut va clignoter à l’afficheur du panneau de commandes. route, contactez Rinnai ou votre agent de service le plus Quand vous appelez pour une de mande d’intervention, proche pour planifier une intervention.
  • Page 81: Fonction De Redémarrage

    Demande d’intervention Fonction de verrouillage activée ● Déverrouiller Coupure de gaz en amont (compteur, Rétablir l'arrivée du gaz ● réservoir ou vanne) ON Timer est définie. Annuler "ON" bois ou push ● remplacer bouton Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 82: Vue En Coupe

    Vue en coupe Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 83: Schéma De Câblage

    FUSIBLE ÉCLATEUR blanc ÉLECTRODE SV1, 2 ÉLECTROVANNE 1,2 jaune VANNE MODULATRICE MOTEUR DE VENTILATEUR DE COMBUSTION gris TRANSFORMATEUR DÉTECTEUR DE PRESSION orange ÉLECTRODE DE DÉTECTION DE W. TH THERMOSTAT MURAL brun FLAMME UNITÉ AFFICHAGE-COMMANDE Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 84: Diagramme En Escalier

    Diagramme en escalier Manuel EX17CT, EX22CT de Rinnai Corporation...
  • Page 85: Garantie

    Rinnai paiera dans les limites du raisonnable le coût de main-d’œuvre associé à la réparation ou au remplace- ment de toute partie ou composant. Toutes les pièces à réparer doivent être des pièces Rinnai d’origine. Toutes les répa- rations et tous les replacements doivent être effectués par un dépanneur individuel ou une société de dépannage ayant reçu l’autorisation de Rinnai.
  • Page 86: Garantie Limitée (Suite)

    Garantie limitée (Suite) Le remplacement du produit ne peut être autorisé que par Rinnai. La société Rinnai ne permet à aucune personne ou société d’assumer pour elle toute obligation ou responsabilité relative au remplacement d’un produit. Si Rinnai détermine que la réparation d’un produit n’est pas possible, Rinnai le remplacera avec un produit comparable, à...
  • Page 87 NOTES Rinnai Corporation EX17CT, EX22CT Manual...
  • Page 88 A tradition of true reliability. For nearly 100 years, we at Rinnai have been fiercely committed to delivering nothing less than a superior experience at every touch point. Beyond manufacturing the highest quality products, our people stand behind all that we make—before, during and long after installation.

Ce manuel est également adapté pour:

Ex22ctRhfe-434fta2Rhfe-559fta2

Table des Matières