2.
Pause function using momentary switch
You can pause the fan for one hour by engaging an external
momentary switch. This can be connected as shown in diagram 3
on page 7.
With this function selected, you will be unable to use the delayed
start via switched live (lighting) function connected to SL
Activation
1 Press the Speed + and Humidity Mode buttons
simultaneously (blue and yellow LEDs flash quickly).
2 Press the timer button and hold it in for 5 seconds until the 5 min
LED comes on.
3 Press the Speed + and Humidity Mode buttons at the same time
(blue and yellow LEDs stop flashing).
Deactivation
1 Press the Speed + and Humidity Mode buttons simultaneously
(blue and yellow LEDs flash quickly).
2 Press the timer button and hold it in for 5 seconds until no timer
run-on LEDs are illuminated.
3 Press the Speed + and Humidity Mode buttons simultaneously
(blue and yellow LEDs flash quickly).
SPEED
TIMER
S
CONSTANT
TIMER
5
MIN
15
30
HUMIDITY
SILENT
MAX
Lo-Carbon iQ Fan
SPEED
TIMER
S
CONSTANT
TIMER
5
MIN
15
30
HUMIDITY
SILENT
MAX
EN