Vent-Axia Lo-Carbon IQ Mode D'emploi page 11

Le ventilateur intelligent pour salles de bains ou toilettes
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.
Pause function using momentary switch
You can pause the fan for one hour by engaging an external
momentary switch. This can be connected as shown in diagram 3
on page 7.
With this function selected, you will be unable to use the delayed
start via switched live (lighting) function connected to SL
Activation
1 Press the Speed + and Humidity Mode buttons
simultaneously (blue and yellow LEDs flash quickly).
2 Press the timer button and hold it in for 5 seconds until the 5 min
LED comes on.
3 Press the Speed + and Humidity Mode buttons at the same time
(blue and yellow LEDs stop flashing).
Deactivation
1 Press the Speed + and Humidity Mode buttons simultaneously
(blue and yellow LEDs flash quickly).
2 Press the timer button and hold it in for 5 seconds until no timer
run-on LEDs are illuminated.
3 Press the Speed + and Humidity Mode buttons simultaneously
(blue and yellow LEDs flash quickly).
SPEED
TIMER
S
CONSTANT
TIMER
5
MIN
15
30
HUMIDITY
SILENT
MAX
Lo-Carbon iQ Fan
SPEED
TIMER
S
CONSTANT
TIMER
5
MIN
15
30
HUMIDITY
SILENT
MAX