Figure
Model number
Rated Flush Volume
Toilet/Urinal type
Control stop inlet
Flush Valve inlet
Flush Valve outlet
Supply water
pressure
Shutoff pressure
Dimension
of cover
Detection range from the front
Detection time
Trap seal protection
Ambient temperature
Water temperature
NOTE:
The type of fixture determines the minimum pressure required for the valve. Consult
fixture manufacturer for the overall pressure requirement.
SPECIFICATIONS
Large cover
Small cover
Large cover
TET2GA
Small cover
TET3GA
1.6 G (6L)
Min
35 psi (241kPa)
(Flowing)
Max*
(Static)
Large cover
Small cover
Automatic flushing every
24 hours of non-use
Toilet
TET2LA
TET2UA
TET3LA
TET3UA
1.28 G (4.8L)
1.0 G (3.8L)
Flush Valve type
1"NPT
1-1/4"NPSM
1-1/2"NPSM
125 psi (862kPa)
7 psi (48kPa)
12-5/8" (H) ×14-3/16"(W)
(320mm(H) ×360mm(W) )
4-23/32" (H) ×4-23/32"(W)
(120mm(H) ×120mm(W) )
Within 33-1/2" (850mm)
32-104˚F (0-40˚C)
34-104˚F (1-40˚C)
4
Urinal
TEU2LA
TEU3LA
0.5 G (1.9L)
Wash down flush
3/4"NPT
15psi (103kPa)
6 seconds
Automatic flushing every
12 hours of non-use
TEU2UA
TEU3UA
0.125 G (0.47L)