Comfort Electronics K4,
Operation, Maintenance, Troubleshooting
34
Program items
(Factory settings)
retrieve/change
Upper reset limit
Starting the program menu:
Press the >42° (
) and
Light (
) buttons for at
least 5 seconds until PAr ap-
pears on the display. Now
press the Mode (
) but-
ton. The display now shows
P00. Press the Mode (
button again to display the
value 42°C. Now use the +/-
buttons to adjust the value
within the 32°C to 42°C lim-
its.
Press the Mode (
) button
to save the setting. The
display shows P00.
The upper and lower reset lim-
its determine the permissible
range for the initial shower
temperature. The system sets
the temperature for the next
shower to 39°C when the tem-
perature is outside this range
when the Shower Panel is
switched off. The temperature
is freely selectable during a
shower.
)
Lower reset limit
Press the + (
) button to
start the next program item
PO1. Press the Mode (
button: The value 32°C ap-
pears. Use the +/- (
and
) buttons to set the value
within the 10°C to 32°C lim-
its. Press the Mode (
)
button to save the setting.
The display shows: PO1
Upper setting limit
The upper setting limit is the
highest tempeature that can
be selected during a shower.
Press the + (
) button to
start the next program item
PO2. Press the Mode (
button: The value 55°C ap-
pears. Use the +/- (
and
) buttons to set the value
within the 40°C to 60°C lim-
its. Press the Mode (
)
button to save the setting.
The display shows: PO2
)
)