8.2 Start process is not being initiated
PA29440A01_00 ENG
OPERATION MANUAL
Check the air pressure
•
Disconnect the compressed air connection (1)
•
Check the air pressure at the manometer (2):
CP-991: 5 bar
CP-992: 5.5 bar
No pressure present:
•
Check whether the compressed air connection is
connected to the compressed air supply
•
Check whether the compressed air supply is O.K.
Pressure is not 5 bar/5.5 bar:
•
Pull the air pressure regulator (3) upwards
•
Set the air pressure by turning (4) to the right (+)
or left (-)
•
Then press the regulator (5) downwards
If the conductor is inserted, the CP-991 will not start.
Check the front door
•
Check that the front door (1) is completely closed and
locked
1
Check the air pressure
•
Check air pressure at the manometer (1):
CP-991: 5 bar
CP-992: 5.5 bar
No pressure present:
•
Check whether the compressed air connection is
connected to the compressed air supply
•
Check whether the compressed air supply is O.K.
Pressure is not 5 bar/5.5 bar:
•
Disconnect the compressed air connection
•
Pull the air pressure regulator (2) upwards
•
Set the air pressure by turning (3) to the right (+) or
left (-)
•
Then press the regulator (4) downwards