© Panduit Corp. 2018
3.6 Dedicated Usage
•
Use the CP-991 only for automatic wire stripping and ferrule crimping.
•
Continuously molded ferrules with cross-sections ranging from #20 – #14 AWG
(0,5 – 2,5mm
•
Only the intended PVC insulated cables may be inserted into the funnel guide of the
CP-991. Never insert solid metal parts or items, the stripping knives would be damaged.
•
Third party reconstruction and changes of the CP-991 beyond retooling are not allowed
because of safety!
3.7
•
Use the CP-991 only when the cover is closed.
•
Before carrying out any work with the cover open (e.g. retooling, maintenance work),
disconnect the CP-991 from the main power supply
•
Make sure that no strange objects are inside the case.
3.8 Places for Use
Avoid operation in the following areas:
•
Damp or dusty places
•
Places exposed to high or low temperatures, or direct sunlight
•
Operating temperature range: 59°F to 95°F (15°C to 35°C)
•
Condensation can form when moving from a cold to a warm place
•
Open cover to evaporate any condensation before using the CP-991
•
Do not spill any liquids over the CP-991
•
Protect the CP-991 from heavy vibrations and jolts
3.9 Safety Devices
•
The CP-991 can be switched OFF through:
o The main switch (O OFF)
o Pulling out the main plug
o Sliding back the cover (by two micro switches)
o The cover is built in for safety. It may not be changed, removed or by-passed by
reconstructions. A label points to existing dangers.
Before opening disconnect main power.
3.10 Authorized user
•
Only authorized and instructed users are allowed to work with the CP-991
•
The user has a responsibility to other persons inside the CP-991 work place
The customer must:
•
Make the operation manual accessible to the user; and
assure that the user has read and understood the manual.
PA29440A01_00 ENG
OPERATION MANUAL
2
) and a strip length of 5/16" (8 mm) must be used.
Dangers
Page: 9 of 26
CP-991 / CP-992
ENGLISH
11-2018