© Panduit Corp. 2018
1
2
7.
Retrofitting
7.1 Changing the cross section
PA29440A01_00 ENG
OPERATION MANUAL
CP-992: Changing the stripping blade
•
Unscrew the Allen screw (1) and take out the old
blade (2)
CP-992
•
Attach the new blade to the guiding pin (3)
•
Adjust the incision depth of the stripping blade to the
conductor to be processed
•
Adjusting the blade changes the incision depth by ±
0.25 mm
•
Tighten Allen screw (1)
•
Check incision depth by stripping a conductor. The
copper strands must not be cut by the stripping
blade.
Preparing the modification
•
Switch off the CP-991 with the main switch (1)
•
Disconnect the main plug (2)
•
Disconnect the compressed air connection (3)
•
Open the front door
Retrofit kits, see Page 12.
Changing the feeder bowl
•
Unscrew the winged screw (1)
•
Move the feeder bowl to the side (2), pull upwards (3)
and empty
•
Attach the feeder bowl in such a way that it slides
into the centering pins and tighten the winged screw
Page: 20 of 26
WARNING: Risk of injury!
The stripping blades are sharp. Be careful not to
injure yourself.
WARNING: Risk of injury!
Disconnect the main plug and the
compressed air before you open the front
door
CP-991: Change the feeder bowl during a
cross section change from 0.5/0.75/1.0/1.5
↔ 2.5
CP-992: Change the feeder bowl every
time the cross section is changed.
NOTE: Ensure that all ferrules are
removed, especially from the slot under
the baffle.
CP-991 / CP-992
ENGLISH