Retrofitting; Changing The Cross Section - Panduit CP-991 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

© Panduit Corp. 2018
1
2
7.

Retrofitting

7.1 Changing the cross section

PA29440A01_00 ENG
OPERATION MANUAL
CP-992: Changing the stripping blade
Unscrew the Allen screw (1) and take out the old
blade (2)
CP-992
Attach the new blade to the guiding pin (3)
Adjust the incision depth of the stripping blade to the
conductor to be processed
Adjusting the blade changes the incision depth by ±
0.25 mm
Tighten Allen screw (1)
Check incision depth by stripping a conductor. The
copper strands must not be cut by the stripping
blade.
Preparing the modification
Switch off the CP-991 with the main switch (1)
Disconnect the main plug (2)
Disconnect the compressed air connection (3)
Open the front door
Retrofit kits, see Page 12.
Changing the feeder bowl
Unscrew the winged screw (1)
Move the feeder bowl to the side (2), pull upwards (3)
and empty
Attach the feeder bowl in such a way that it slides
into the centering pins and tighten the winged screw
Page: 20 of 26
WARNING: Risk of injury!
The stripping blades are sharp. Be careful not to
injure yourself.
WARNING: Risk of injury!
Disconnect the main plug and the
compressed air before you open the front
door
CP-991: Change the feeder bowl during a
cross section change from 0.5/0.75/1.0/1.5
↔ 2.5
CP-992: Change the feeder bowl every
time the cross section is changed.
NOTE: Ensure that all ferrules are
removed, especially from the slot under
the baffle.
CP-991 / CP-992