30
5.3
MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES
EN EN
THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS
SUCH AS BRICK, MARBLE, GRANITE, ETC., AS LONG AS THESE MATERIALS NEVER OVERHANG
IMPORTANT: The LV50 requires a minimum inside enclosure height of 75 1/4" (1911.4mm), measured
from the bottom of the appliance. For temperature requirements, this area must be left unobstructed. It is
recommended that the enclosure be ventilated at the top and bottom to circulate the hot air.
Before fi nishing in the appliance test the operation using the remote control, cycling it through all of its different
modes, see "OPERATION" section. Check pressure readings, see "PILOT BURNER ADJUSTMENT" section.
Once fi nished in, access to the control components can only be done through the inside of the appliance.
75 1/4"
1911mm
MINIMUM
ENCLOSURE
HEIGHT
APPLIANCE
* Within the appliance enclosure a 6" (152mm) clearance between the top of the vent pipe and combustible
materials is required. All other clearances within the enclosure, including where the vent pipe exits the
enclosure are subject to 2" (51mm) to the sides and bottom and 3" (76mm) to the top for horizontal and 1"
(25mm) for vertical.
** See venting section.
W415-1439 / A / 07.10.15
INTO THE APPLIANCE OPENING.
NOTE: JOINT COMPOUNDS AND TAPES THAT ARE RESILIENT
TO HEAT AND CRACKING SHOULD BE USED WHEN TAPING
AND MUDDING SEAMS.
STEEL STUD
HEAT SHIELD
FRAME
26 1/2"
673mm
MINIMUM
TOP OF
25 5/8"
OPENING
651mm
MINIMUM
NON-COMBUSTIBLE
COMBUSTIBLE
MATERIAL
WARNING
!
6"
TOP OF ENCLOSURE
152mm *
7" 178mm
TO SIDEWALL
NON-COMBUSTIBLE
0" IF NON-COMBUSTIBLE
COMBUSTIBLE
FINISHING IS USED SUCH
AS BRICK AND STONE.
3"
76mm
2"
51mm
65 1/4"
1657mm
MINIMUM
PLUS RISE**