Description
Th e DC 5800c 9.2/11 kW S is driven by a two stage con-
nected turbopump with extremely high vacuum eff ekt.
Th e machine is intended for use on material transporta-
tion systems or for cleaning of abnormally heavy material.
With theese types of systems it is recommended to use a
preseparator.
Th e high vacuum eff ect can also be used in conven-tional
systems where extra long hose or pipe systems are required.
Filter cleaning is done with reverse pulse which gives excel-
lent fi lter economy.
Th e extraction system functions with negative pressure (va-
Operation
Connect the machine to a suitable power source according to
the specifi cation plate on the machine. If the electrical cord
on the machine becomes damaged it should be replaced.
Th e fi lter should be cleaned 1-2 times per day with conti-
nuous running or if the machine is equipped with a fi lter
monitor, when this is in the red area.
For fi lter cleaning:
1.
Start the machine.
2.
Close the shutter valve on the machines inlet.
3.
With slow, even motion open the pulse top by lifting
the handle. Repeat three to six times.
4.
Open the shutter valve.
5.
If the fi lter condition meter reads green work can con-
tinue, if in the red, pulse clean again. If after several
repetitions, the fi lter condition still shows red the fi ne
fi lter must be changed.
2010-10-20
cuum) that draws the air through suction casings/nozzles,
hose system, separator and fi lter system. Coarse separation
of dust occurs in the units cyclone which is a highly effi cient
separator for larger particulate. Th e fi ne dust is separated
and contained by the units fi lter system. Separated material
is collected for disposal in the plastic sack or container at
the base of the cyclone.
Th e plastic sack should be changed only after the fi lter has
been cleaned. Th e sack should be changed when the dust
level is about 5 cm under the foot valve. Th e plastic sack
should be sealed after removal from the machine.
Use only original plastic sacks.
DC 5800c 9,2/11 kW S - 9
Part No 9091