Safety Considerations
Read all instructions before attempting to operate this
machine and save these instructions.
Warning! When using electric machines, basic safety
precuations should always be
risk of fi re, electric shock and personal injury, including
the following:
1.
Work area environment
Don´t expose the machine for rain. Don´t use it in
damp or wet locations or in presence of fl ammable
liquids or gases.
2.
Overload
Never let the machine operate fully throttled. Always
follow the regulations pertinent to the
material you are working with ie asbestos. Don´t use
the machine for purposes that it isn´t
intended for.
3.
Body injuries
Never let the suction come in contact with parts of
the body. Th e strong suction eff ect can
hurt the blood-vessels in the skin. Do not repair the
electric components yourself, get
somebody qualifi ed. Faults may cause injury. See also
below under warnings.
4.
Don´t abuse cord
Never pull the machine by cord. Keep cord from
heat and sharp edges. Check the electric cable regu-
larly if damage.
TECHNICAL DATA
HxWxL
Weight
Inlet
Collecting sack 50 l
Hose length (φ 50)
Flow, max
Neg. pressure, max
Power consumption
Fine fi lter polyester, area
Degree of separation
(DIN 24184/3)
Filter area, microfi lter
Degree of separation,
microfi lter (DOP)
Sound level */
followed to reduce the
50 Hz
60 Hz
1800x760x1150 mm
ca 200 kg
ca 220 kg
φ 76 mm
φ 76 mm
kPa
700 x 850 mm
40
5-50 m
5-50 m
3
3
500 m
/h
560 m
/h
40 kPa
45 kPa
9.2 kW
11 kW
20
2
2
4.8 m
4.8 m
99.9 %
99.9 %
2
2
2.5 m
2.5 m
> 99,97 %
> 99,97 %
< 75 dB(A)
< 75 dB(A) */ Sound level at 1.6 m height and 1 m distance accor-
DC 5800c 9,2/11 kW S - 8
5.
Important measure
With cleaning and maintenance on the machine,
the power cable should be dis-connected from the
supply.
6.
Maintain the machine with care
Keep machine clean and check that the hose is enti-
red and that all gaskets are tight. Follow instructions.
Keep handles dry and free from oil and grease.
7.
Checking of damage
Before futher use of the machine it should be care-
fully checked that the machine is unda-maged. If
there are any damaged parts these should be repaired
by of a Dustcontrol authorized service center.
8.
Warning
Use only accessories and replacable parts which are
available in Dustcontrol catalogue. When using
faulty parts or pirate parts (espe-cially fi lter) the
machine could leak out unhealthy dust which can
cause personal injuries.
Vacuum producer capacity
11 kW S 60 Hz
9.2 kW S
200
400
ding to DIN EN ISO 3744 in free space and at maximum
airfl ow.
600
800
1000
Part No 9091
m
3
/h