INSTALLATION REQUIREMENTS

ELECTRICAL

A properly-grounded horizontally- mounted electri-
cal receptacle should be installed no higher than
3" (7.6 cm) above the fl oor, no less than 2" (5 cm)
and no more than 8" (20,3 cm) from the left side
(facing product).
Check all local code requirements.

GAS

An agency-approved, properly-sized manual
shut-off valve should be installed no higher than
3" (7.6 cm) above the fl oor and no less than 2" (5
cm) and no more than 8" (20.3 cm) from the right
side (facing product).
To connect gas between shut-off valve and regula-
tor, use agency-approved, properly sized fl exible
or rigid pipe. Check all local code requirements.
installation area for the connection
10

ELECTRICAL CONNECTION

Warning!
ELECTRICAL SHOCK HAZARD
Disconnect electrical power at the circuit bre-
aker box or fuse box before installing the ap-
pliance.
Provide appropriate ground for the appliance.
Use copper conductors only.
Failure to follow these instructions could re-
sult in serious injury or death.
Warning!
Electrical grounding
This appliance is equipped with a three-prong
plug for your protection against shock hazard and
should be plugged directly into a properly groun-
ded socket. Do not cut or remove the grounding
prong from this plug.
Caution
Label all wires prior to disconnecting when
servicing controls. Wiring errors can cause
improper and dangerous operation.
Verify proper operation after servicing.
The appliance shall be connected to a single pha-
se electric line rated at 120/208Vac or 120/240Vac
and 60Hz frequency.
Type
Voltage
30" DFM 120/208V
120/240V
30" DFS
120/208V
120/240V
36" DFM 120/208V
120/240V
36" DFS
120/208V
120/240V
48" DFM 120/208V
120/240V
48" DFS
120/208V
120/240V
Install a suitable electric power supply receptacle
connection type NEMA 14-50R able to support a
load of at least 30 A (per line) according to local
code requirements. For four or three wires power
supply connection system see diagram below.
Circuit rating
Electrical
supply
2900W 14A
20A
3700W 16A
20A
4300W 21A
30A
5600W 24A
30A
2900W 14A
20A
3700W 16A
20A
4500W 22,5A
30A
5900W 25,5A
30A
5400W 30A
40A
6700W 33A
40A
6800W 36,5A
40A
8500W 40,5A
40A