BONFIGLIOLI Vectron ACTIVE CUBE Série Guide Rapide page 96

Masquer les pouces Voir aussi pour Vectron ACTIVE CUBE Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

No signals at digital inputs S1IND (STOA) and S7IND
(STOB). If signals were already applied at the beginning of
the guided commissioning, the "StO" message is not
displayed.
GB
Confirm the final "rEAdY" message by pressing the
ENT key.
Cancelling the operation with the ESC key or withdrawing
the enable signal S1IND (STOA) or S7IND (STOP) results in
an incomplete take-over of the values.
Confirm the "End" display by pressing the ENT key.
The guided commissioning of the frequency inverter is
terminated via a reset and the initialization of the frequency
inverter. The relay output X10 signals a fault.
After successful initialization of the frequency inverter, the
factory-set parameter Actual Frequency 241 is displayed.
The drive is accelerated to the set Min. frequency 418
(default 3.50 Hz) by:
 Signals at digital inputs S1IND (STOA) and S7IND
(STOB) and
Start clockwise by rising signal edge at S2IND or Start
anticlockwise by rising signal edge at S3IND
94
For release of the output stage, wiring of digital inputs S1IND
(STOA) and S7IND (STOB) is required.
In the case of more demanding requirements regarding the
accuracy of the speed/torque control, you should carry out the
guided commissioning procedure once again under operating
conditions because part of the machine data depends on the
operating temperature.
During this procedure, confirm the rated machine values
already entered.
Quick Start Guide ACU
10/18

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vectron active cubeAcu210Acu410Acu510Acu610

Table des Matières