BONFIGLIOLI Vectron ACTIVE CUBE Série Guide Rapide page 119

Masquer les pouces Voir aussi pour Vectron ACTIVE CUBE Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

8.10.3 ACU610 (160.0...400.0 kW, 690 V)
Type
ACU610
Output, motor side
Recommended motor
shaft power
Output current
I Longt ovrld (60 s)
I Shortt ovrld (1 s)
2)
Output, braking resistor
Min. braking resistance
Recommended resistr
(U
= 770 V)
dBC
Input, mains side
I Power supply
6)
U Mains
Fuses
8)
Ambient conditions
Energy dissipation (2 kHz
switching frequency)
Output current (Maximum current in continuous operation)
Frequency inverter
nominal power
160 kW
200 kW
250 kW
315 kW
355 kW
400 kW
1)
Power reduction with torsional frequencies below 15 Hz
2)
Only with torsional frequencies above 15 Hz
6)
Rated value with recommended motor power, 690V mains voltage and mains
inductance UK=4%
8)
Semiconductor fuses recommended (e.g. Bussmann Type 170M)
10/18
P
kW
I
A
eff.
1)
I
A
eff.
I
A
eff.
R
Ω
3.00
R
Ω
5.00
I
A
U
V
I
A
P
W
3200
2 kHz
180
230
280
350
400
450
Quick Start Guide ACU
-51
-53
-55
160
200
250
180
230
280
270
350
420
330
420
510
3.00
3.00
5.00
5.00
160
200
250
690 (for UL reduced: 600)
250
315
350
3950
4500
Switching frequency
4 kHz
180
230
280
350
400
436
-57
-59
-61
315
355
400
350
400
450
530
600
675
630
720
750
1.80
1.80
1.80
3.00
3.00
3.00
320
360
410
450
500
550
5500
6250
6900
8 kHz
180
230
280
350
400
410
117
GB

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vectron active cubeAcu210Acu410Acu510Acu610

Table des Matières