ADJUSTING MAXIMUM OUTLET TEMPERATURE

1) Shut the water off at the stop valves.
2) To decrease temperature:
Remove screw and pull handle slowly to
one notch and reinstall onto cartridge.
To increase temperature:
Remove screw and pull handle slowly to
notch and reinstall onto cartridge.
3) Secure handle with screw.
4) Open shut off valve.
5) Check water temperature.
**Repeat steps 1 - 5 if necessary
ADJUSTING OUTLET TEMPERATRURE
1) To decrease temprature: turn handle
clockwise.
2) To increase temprature: turn handle
counter-clockwise.
ACCESSING ANG CLEANING THE VALVE
1) Shut the water off at the stop valves.
2) Disconnect supply hoses.
3) Pull out the strainer and clean it with a
brush.
4) Reinstall the clean strainer and connect
water supply hoses.
5) Open the stop valves.
Strainer
Brush
5
Strainer
Strainer